Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home

Residential

Major Projects
  • Custom New Homes
  • Additions & Renovations
  • Muskoka Cottages & Homes
  • Exterior Walls
  • Interior Ceiling Sound Dampening
Targeted Areas
  • Basements
  • Attics & Roof Decks
  • Crawl Spaces
  • Rim Joist Headers
  • Garages & Floors Over Garage
  • Cathedral Ceilings
  • Cantilevers & Overhangs
  • Under-Slab & Radiant Floors
  • Cold Rooms
  • RVs & Vans
  • Swimming Pools

Commercial

Buildings & Facilities
  • Commercial SPF & Fire Coating
  • Warehouse & Industrial
  • Metal Buildings
  • Barns & Agricultural
  • Multi-Unit Buildings
  • Flat Roof Systems
Specialty
  • Shipping Containers
  • Silos & Water Tanks

Code & Expert Guides

  • What is Spray Foam?
  • Cost of Spray Foam
  • Our Sprayfoam Chemicals
  • Certifications & Standards
  • Spray Foam Knowledge Base
Ontario Code & ULC Guides
  • Ontario R-Value & Code Guide
  • CAN/ULC-S705.2 Code Rules
  • Open-Cell vs. Closed-Cell

Thermal Barriers (Foam)

Core Systems
  • DC315 Intumescent Coating
  • Sprayfoam & Fire Coating (2-in-1)
Where Code Requires It
  • Mechanical & Furnace Rooms
  • Exposed Basements & Crawls
  • Attached Garage Ceilings
  • Warehouse Exposed Foam Decks
  • Unvented Attics & Roof Decks
  • Rim Joists & Floor Headers

Structural Fireproofing

Fireproofing Systems
  • Cementitious Fireproofing (SFRM)
  • Intumescent Fire Coating (Thin-Film)
Structural Assemblies
  • Structural Beams & Columns
  • Metal Floor & Roof Decks
  • Commercial Parkades & Garages
  • Architectural Exposed Steel (AESS)
  • Request Fire Spec & Quote

Code & Expert Guides

  • What is DC315 Fire Coating?
  • Cost of DC315 Fire Coating
  • Our Fire Coating Chemicals
  • Certifications & Standards
  • Fire Coating Knowledge Base
Ontario Code & ULC Guides
  • Ontario 15-Min Thermal Barrier
  • ULC 1–4 Hr Steel Ratings
  • DC315 vs. Type X Drywall
Locations
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviews
Contact UsGet My Pricing
Serving GTA & Beyond
Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home
Spray Foam Services
Overview & Guides
What is Spray Foam?Cost of Spray FoamOpen-Cell vs. Closed-CellOntario R-Value & Code Guide
Project Applications
Custom New HomesAdditions & RenovationsMuskoka Cottages & HomesExterior WallsInterior Ceiling Sound DampeningBasementsAttics & Roof DecksCrawl SpacesRim Joist HeadersGarages & Floors Over GarageCathedral CeilingsCantilevers & OverhangsUnder-Slab & Radiant FloorsCold RoomsRVs & VansSwimming Pools
Overview & Guides
Commercial SPF & Fire Coating OverviewCAN/ULC-S705.2 Code RulesCost of Spray Foam
Project Applications
Warehouse & IndustrialMetal BuildingsBarns & AgriculturalMulti-Unit BuildingsFlat Roof SystemsShipping ContainersSilos & Water Tanks
Overview & Guides
Our Sprayfoam ChemicalsCertifications & StandardsSpray Foam Knowledge Base
Fire Coatings
Overview & Guides
DC315 Fire Coating OverviewSprayfoam & DC315 Package (2-in-1)What is DC315 Fire Coating?Cost of DC315 Fire CoatingDC315 vs. Type X DrywallOntario 15-Min Thermal Barrier
Project Applications
Mechanical & Furnace RoomsExposed Basements & CrawlsAttached Garage CeilingsWarehouse Exposed Foam DecksUnvented Attics & Roof DecksRim Joists & Floor Headers
Overview & Guides
Intumescent Fire Coating OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Structural Beams & ColumnsArchitectural Exposed Steel (AESS)Request Fire Spec & Quote
Overview & Guides
Cementitious Fireproofing OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Metal Floor & Roof DecksCommercial Parkades & GaragesRequest Fire Spec & Quote
Overview & Guides
Our Fire Coating ChemicalsCertifications & StandardsFire Coating Knowledge Base
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviewsContact Us
More Info & Resources
› About Us› Certifications› All Services› Blog & Guides
We Serve GTA & Across Ontario!
Get My Pricing 647-333-3626
Home/Fire Coatings & Spray Foam/Combined Spray Foam & DC315 Package
2-IN-1 TURNKEY PACKAGE
5.0 Google Rating (45+ Reviews)·CAN/ULC-S705.2 & S124 Certified

Combined Spray Foam & DC315 Fire Coating in Toronto & Ontario

Insulate and fire-rate your building in one coordinated mobilization. Our certified crews install 2 lb closed-cell spray foam and single-coat IFTI DC315® thermal barrier—saving $3.50–$5.00/sq ft vs. framing and drywall.

2026 Quick Summary
Bundling 2 lb closed-cell spray foam (CAN/ULC-S705.1) with IFTI DC315® intumescent thermal barrier coating (CAN/ULC-S124) costs $4.25–$7.85/sq ft installed across Ontario. One certified crew delivers R-12 to R-31+ insulation plus a mandatory 15-minute Ontario Building Code thermal barrier with full permit documentation.
Get Your Instant Project Estimate in 60s →(647) 333-3626
Caliber CAN/ULC-S705.2 + CCMC #14036-R
Same-Day Foam + DC315® Option
Combined closed-cell spray foam insulation and DC315 thermal barrier fire coating in Ontario
2-in-1 Turnkey Closed-Cell Spray Foam + IFTI DC315® Fire Coating Package

Get Your Free Quote

Takes 10 seconds — we'll call you back.

Free Estimate No Obligation WSIB Cleared Licensed Caliber Certified
Call 647-333-3626 (7AM–9PM)
Have Blueprints or Steel Schedules? Email drawings to info@spfsolutions.ca for 24-hour fireproofing takeoffs & pricing.
Dual-Phase System

How Our 2-in-1 Spray Foam + DC315 Thermal Barrier Works

Built for warehouses, metal buildings, basements, crawl spaces, mechanical rooms, and garages where exposed foam requires Ontario Building Code protection.

Phase 01: Smooth-Profiled 2 lb Closed-Cell Spray Foam (CAN/ULC-S705.1)

PHASE 01:2.0 lb Closed-Cell Spray Foam

Monolithic thermal, air, and Class II vapour barrier sprayed to a smooth, coating-ready profile.

Governing StandardCAN/ULC-S705.1 & S705.2 Certified
Applied Depth & R-Value2.0" – 5.0" (R-12 to R-31+)
Cure & Topcoat WindowTack-Free in 60s • Coat in 1–2 Hrs
  • Stops air leakage (<0.02 L/s·m²) & steel roof condensation
  • Built-in Class II vapour barrier (<60 ng/Pa·s·m²) — no poly needed
  • Sprayed by Caliber Certified (CAN/ULC-S705.2 Licensed) Installers
Phase 02: High-Build 18–21 Mil WFT IFTI DC315® Intumescent Pass

PHASE 02:IFTI DC315® Intumescent Fire Coating

Single-coat airless application delivering mandatory Ontario Building Code fire protection without drywall.

Governing StandardCAN/ULC-S124 & CCMC #14036-R
Applied Film Thickness18–21 mils WFT (12–14 mils DFT)
Fire Protection Rating15-Min Thermal & Ignition Barrier
  • Expands 35x–50x at 200°C+ into an insulating carbon char shield
  • Complies with Ontario Building Code 9.10.17.10.(1) & 3.1.4.2
  • Includes signed WFT/DFT gauge log & CCMC Permit Certificate
CAD ARCHITECTURAL CROSS-SECTION

Substrate → 2 lb Closed-Cell SPF → IFTI DC315® Thermal Barrier

BASE /SUBSTRATE
LAYER 01 — Steel Deck, Concrete or Wood JoistsSUBSTRATE
2.0"–5.0" /PHASE 01 SPF
LAYER 02 — 2 lb Closed-Cell Spray Foam (R-12–R-31+)CORE HELD < 140°C
35x–50x /PHASE 02 DC315
LAYER 03 — DC315® Carbon Char Shield50x EXPANSION
800°C+ /FIRE ZONE
LAYER 04 — 800°C+ Room Fire Exposure15-MIN PASS

* Phase 1 (2 lb Closed-Cell Spray Foam) + Phase 2 (18–21 mils IFTI DC315®) expands 35x–50x at 200°C+ into a carbon char shield that protects the foam core from ignition for 15+ minutes.

SPRAY FOAM & FIRE COATING EXPERTS

2 lb Closed-Cell Spray Foam + IFTI DC315® in 1 Mobilization
★★★★★5.0 Google Rating•55+ Verified Reviews•Serving Across Ontario
STEP 1: 60-SECOND PRICE CHECK
LOCK IN DIRECT CONTRACTOR PRICING

Fast Response & Quotes · No Commitment!

Tap to Select Your Project:
or call directly: 647-333-3626
VERIFIED, CERTIFIED & LISTED ON
Google5.0 ★ Verified
HomeStarsVerified Pro
Houzz ProListed Contractor
TrustedProsCanadian Directory
Caliber CertifiedCAN/ULC-S705.2
WSIB & CCMCOntario Cleared
Turnkey Advantage

Why Builders & Facility Managers Choose One Certified Contractor for Both Phases

Verified Inter-Coat Adhesion

Our certified team controls both the closed-cell foam surface profile and DC315® coating application, preventing peeling or failed inspections.

Single-Mobilization Turnaround

Because 2 lb closed-cell foam cures rapidly, our crew transitions directly from foam proportioners to airless DC315 rigs in one coordinated visit.

Unified Permit Closeout Package

Receive both your Caliber CAN/ULC-S705.2 Spray Foam Placard and your signed CCMC #14036-R Thermal Barrier Certificate together.

2026 Bundle Pricing

2026 Combined Spray Foam + DC315 Fire Coating Cost

Save 15%–25% by bundling both phases in a single mobilization with unified municipal permit documentation.

UTILITY & GARAGE BUNDLE

Mechanical Room, Rim Joist or Garage Package

$5.25 – $7.85/ sq ft turnkey

Complete 2 lb closed-cell spray foam + certified IFTI DC315® thermal barrier for exposed residential zones.

  • 2.0"–3.5" Closed-Cell SPF (R-12 to R-21) + DC315
  • Full masking of HVAC ducts, boilers, pipes & panels
  • Meets Ontario Building Code Sentence 9.10.17.10.(1)
  • Includes both Caliber & CCMC #14036-R certificates
Get My Price in 60s →
MOST POPULAR

Unfinished Basement, Crawl Space or Cathedral Deck

$4.50 – $6.95/ sq ft turnkey

Insulate and fire-rate exposed foundations, crawl spaces, or unvented attics without stud framing or drywall.

  • Continuous CAN/ULC-S705.1 air, thermal & vapour seal
  • 18–21 mils WFT / 12–14 mils DFT IFTI DC315® topcoat
  • Saves $3.50–$5.00/sq ft vs. stud framing + 1/2" drywall
  • 1-Day Turnaround + Full Municipal Sign-Off Pack
Get My Price in 60s →
COMMERCIAL & WAREHOUSE

Industrial Corrugated Deck & Wall Turnkey System

$4.25 – $6.85/ sq ft (volume rate)

High-production closed-cell foam + DC315 thermal barrier for warehouses, metal shops, Quonsets & Sea-Cans.

  • Stops steel roof sweating & cuts heating load by 40%+
  • Ontario Building Code Division B Article 3.1.4.2 compliant
  • High-reflectance Ice White, Grey or Charcoal Black finish
  • Scissor-lift commercial crews (5,000–12,000 sq ft/day)
Request Commercial Bid →
Turnkey Application ScopePhase 1: Closed-Cell SPF SpecPhase 2: DC315 Fire Coating Spec2026 Combined Rate / Sq FtSavings vs. Framing + Drywall
Commercial Warehouse / Metal Building Deck2.0"–3.0" Closed-Cell (R-12 to R-18)18–21 mils WFT (Ice White / Charcoal)$4.25 – $6.85 / sq ftSaves 100% of strapping & boarding cost
Unfinished Basement & Crawl Space Walls2.5"–3.5" Closed-Cell (R-15 to R-21)18 mils WFT / 12 mils DFT (CAN/ULC-S124)$4.50 – $6.95 / sq ftSaves $3.50–$5.00/sq ft vs. studs + drywall
Mechanical, Furnace & Boiler Utility Rooms3.5" Closed-Cell SPF (R-21)18–21 mils WFT over tight pipe/duct bays$5.25 – $7.85 / sq ftPasses inspection where drywall cannot fit
Attached Garage Ceiling Under Bonus Room5.0" Closed-Cell SPF (R-31 + Gas Seal)18–21 mils WFT across exposed joists/beams$5.75 – $8.25 / sq ftDual thermal + Ontario Building Code fire pass
20ft / 40ft Shipping Container (Sea-Can)2.0"–3.0" Closed-Cell SPF (Zero Sweat)18 mils WFT Durable Interior Latex Finish$2,650 – $5,450 (Full Container)Preserves 100% of interior cargo width
Request Your Turnkey 2-in-1 Project Estimate
Includes Both Caliber CAN/ULC-S705.2 & Signed CAN/ULC-S124 Compliance Certificates
Get My Price in 60s →
Ontario Installations

Recent Turnkey Spray Foam & Fire Coating Projects

18,500 Sq Ft Corrugated Steel Roof & Wall Envelope
COMMERCIAL WAREHOUSE • MISSISSAUGA

18,500 Sq Ft Corrugated Steel Roof & Wall Envelope

2.5" Closed-Cell SPF (R-15) + 18 mils WFT IFTI DC315® Ice White

Eliminated roof condensation, cut heater runtime by 42%, and passed Part 3 fire inspection on the first visit.

Hydronic Boiler Room, Rim Joists & 3-Car Garage Ceiling
CUSTOM HOME MECHANICAL & GARAGE • TORONTO

Hydronic Boiler Room, Rim Joists & 3-Car Garage Ceiling

3.5"–5.0" Closed-Cell SPF (R-21/R-31) + 21 mils WFT DC315 Light Grey

Encapsulated congested PEX manifolds, ERV ductwork, and steel beams where 1/2" drywall could not fit.

40x80 Steel Equipment Facility & Heated Workshop
AGRICULTURAL & METAL SHOP • VAUGHAN / KING

40x80 Steel Equipment Facility & Heated Workshop

3.0" Closed-Cell SPF (R-18) + 18 mils WFT DC315 Bright White

Delivered a bright-white thermally sealed interior with full municipal building permit sign-off.

2,200 Sq Ft Exposed Foundation & Crawl Space
UNFINISHED BASEMENT & CRAWL • OAKVILLE

2,200 Sq Ft Exposed Foundation & Crawl Space

3.5" Closed-Cell SPF (R-21) + 18 mils WFT DC315 Matte White

Saved $8,400 compared to framing perimeter stud walls and hanging drywall while passing occupancy inspection.

Submittal Data

Dual-Phase Specification Ledger

Phase 1 Spray Foam Standard & Licensing
CAN/ULC-S705.1 Closed-Cell SPF installed per CAN/ULC-S705.2 by Caliber Licensed Installers
Phase 2 Thermal Barrier Standard & Listing
CAN/ULC-S124 15-Minute Protective Covering • CCMC #14036-R • NFPA 286 Tested
Ontario Building Code Compliance
Ontario Building Code Sentence 9.10.17.10.(1) (Part 9) & Division B Article 3.1.4.2 (Part 3)
Approved CCMC Spray Foam Chemical Systems
BASF Walltite® Eco v.3, Huntsman Building Solutions (Icynene/Demilec), Johns Manville & other approved CCMC spray foam chemicals
Approved Thermal Barrier Coating Systems
IFTI DC315® Intumescent Thermal Barrier Coating (CCMC 14036-R / UL ER13475-01), No-Burn® Plus ThB, Flame Control® No. 60-60A & other approved CAN/ULC-S124 / CCMC intumescent thermal barrier coatings
Combined Thermal, Air & Vapour Performance
LTTR R-6.0/in • Air Permeance < 0.02 L/(s·m²) • Class II Vapour Retarder (< 60 ng/Pa·s·m²)
Required Fire Coating Film Build
18–24 mils WFT curing to 12–16 mils DFT verified via calibrated gauges
Unified Permit Closeout Package
Caliber CAN/ULC-S705.2 Placard + Signed CCMC #14036-R Certificate + WFT/DFT Log
Turnkey Package FAQs

Frequently Asked Questions About Combined Spray Foam & Fire Coating

In 2026 across Toronto and Ontario, our turnkey 2-in-1 Closed-Cell Spray Foam + IFTI DC315® Intumescent Fire Coating package costs $4.25 to $6.85 per sq ft for commercial warehouses and metal buildings, $4.50 to $6.95 per sq ft for unfinished basements and crawl spaces, and $5.25 to $8.25 per sq ft for mechanical rooms and R-31 garage ceilings. Bundling both phases saves 15% to 25% compared to hiring separate contractors.
Hiring separate trades means double mobilization fees, scheduling delays, and risk of coating delamination if the foam was sprayed with a rough texture. Our Caliber Certified (CAN/ULC-S705.2 Licensed) Spray Foam Installers spray a smooth, coating-ready foam profile and apply calibrated IFTI DC315® under one unified permit compliance package.
Yes. Because 2 lb medium-density closed-cell spray polyurethane foam cures tack-free in under 60 seconds and dissipates heat within 1 to 2 hours, our crew can insulate your zone in the morning and apply the 18–21 mil WFT pass of IFTI DC315® that same afternoon.
Yes. Under Ontario Building Code Sentence 9.10.17.10.(1) and Division B Article 3.1.4.2, foamed plastic insulation must be protected by 1/2-inch gypsum drywall OR an approved thermal barrier tested to CAN/ULC-S124. Because IFTI DC315® holds CCMC Evaluation Report #14036-R and CAN/ULC-S124 certification, no framing or drywall is required.
You receive a complete 2-part Municipal Permit Sign-Off Package: (1) your official Caliber CAN/ULC-S705.2 Spray Foam Installation Certificate & Site Placard, and (2) your signed CCMC #14036-R / CAN/ULC-S124 Thermal Barrier Verification Certificate documenting batch numbers and verified WFT/DFT gauge logs.
IFTI DC315® has completed full-scale CAN/ULC-S124 and NFPA 286 fire testing over all major Canadian CCMC-approved spray foam systems we install, including BASF Walltite® Eco v.3, Huntsman Building Solutions (Icynene / Demilec Heatlok HFO), Johns Manville & other approved CCMC spray foam chemicals.
IFTI DC315® is manufactured in four architectural and industrial colours: Ice White, Light Grey, Dark Grey, and Charcoal Black.
Use our 60-Second Interactive Project Estimator at /price-chat or call our Toronto & Ontario engineering desk directly at (647) 333-3626 for priority 48–72hr scheduling.

How to Fireproof Spray Foam Insulation in Ontario (2026 Code Guide)

Read Technical Guide →

DC315 Fire Coating Cost in Ontario (2026 Price Per Sq Ft Guide)

Read Technical Guide →

Commercial Warehouse Spray Foam & Fire Coating Cost in Ontario

Read Technical Guide →

Ontario Building Code Rules for Spray Foam & Thermal Barriers

Read Technical Guide →

SPRAY FOAM & FIRE COATING EXPERTS

2 lb Closed-Cell Spray Foam + IFTI DC315® in 1 Mobilization
★★★★★5.0 Google Rating•55+ Verified Reviews•Serving Across Ontario
STEP 1: 60-SECOND PRICE CHECK
LOCK IN DIRECT CONTRACTOR PRICING

Fast Response & Quotes · No Commitment!

Tap to Select Your Project:
or call directly: 647-333-3626
VERIFIED, CERTIFIED & LISTED ON
Google5.0 ★ Verified
HomeStarsVerified Pro
Houzz ProListed Contractor
TrustedProsCanadian Directory
Caliber CertifiedCAN/ULC-S705.2
WSIB & CCMCOntario Cleared

Proudly Serving Toronto, GTA & All of Ontario

Direct contractor pricing · CAN/ULC-S101 & S124 Certified · $0 Travel Fee Across Ontario

Sprayfoam Solutions service coverage map across Toronto, GTA and Ontario
50+ Cities & Municipalities

With regional mobile crews stationed right near you, we charge $0 travel fees and stand as the best, most trusted contractor to serve your home or commercial building anywhere in Ontario.

WSIB Insured
6,500+ Projects Completed
Calculate Estimate →

Get Your Free Quote

Takes 10 seconds — we'll call you back.

Free Estimate No Obligation WSIB Cleared Licensed Caliber Certified
Call 647-333-3626 (7AM–9PM)
SERVING ALL ONTARIO:Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock•Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock

About Sprayfoam Solutions Toronto Inc

6,500+ projects completed since 2008. The Greater Toronto Area's trusted spray foam insulation & fireproofing contractor for commercial builders, general contractors, and homeowners.

647-333-3626Request a Quote
50 Howden Rd, Scarborough, ON M1R 3E4
100% Canadian Owned & OperatedLicensed • Up to $10M Insured • WSIB Clearance

Our Services

  • ›Spray Foam (Residential)
  • ›Spray Foam (Commercial)
  • ›Interior Sound Dampening
  • ›Fire Coating DC315
  • ›Cementitious Fireproofing
  • ›Intumescent Coating

Expert Guides

  • What is Spray Foam Insulation?
  • How Much Does Spray Foam Cost?
  • Our Chemicals & Technical Data
  • Customer Reviews (5.0 ★)
  • View Our Projects
  • Book Free On-Site Inspection

Areas We Serve

  • •Toronto & Central GTA
  • •Mississauga & Peel
  • •Oakville & Halton
  • •Vaughan & York Region
  • •Barrie & Simcoe County
  • •Muskoka & Cottage Country
  • •Waterloo & Tri-Cities
  • •Oshawa & Durham Region
  • + View All 50+ Cities
All project estimates, pricing illustrations, R-value metrics, and building code references on this website are for general informational purposes only and do not constitute a certified estimate or binding offer to contract. Formal written contracts provided by Sprayfoam Solutions Toronto Inc. following an on-site inspection strictly supersede all online representations. Subject to our Terms of Service and Privacy Policy.
AboutView Our WorkCustomer Reviews 5.0 ★CertificationsServicesAreas We ServeBlogContact UsTerms of ServicePrivacy Policy
© 2026 Spray Foam Solutions Toronto Inc. All Rights Reserved.