Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home

Residential

Major Projects
  • Custom New Homes
  • Additions & Renovations
  • Muskoka Cottages & Homes
  • Exterior Walls
  • Interior Ceiling Sound Dampening
Targeted Areas
  • Basements
  • Attics & Roof Decks
  • Crawl Spaces
  • Rim Joist Headers
  • Garages & Floors Over Garage
  • Cathedral Ceilings
  • Cantilevers & Overhangs
  • Under-Slab & Radiant Floors
  • Cold Rooms
  • RVs & Vans
  • Swimming Pools

Commercial

Buildings & Facilities
  • Commercial SPF & Fire Coating
  • Warehouse & Industrial
  • Metal Buildings
  • Barns & Agricultural
  • Multi-Unit Buildings
  • Flat Roof Systems
Specialty
  • Shipping Containers
  • Silos & Water Tanks

Code & Expert Guides

  • What is Spray Foam?
  • Cost of Spray Foam
  • Our Sprayfoam Chemicals
  • Certifications & Standards
  • Spray Foam Knowledge Base
Ontario Code & ULC Guides
  • Ontario R-Value & Code Guide
  • CAN/ULC-S705.2 Code Rules
  • Open-Cell vs. Closed-Cell

Thermal Barriers (Foam)

Core Systems
  • DC315 Intumescent Coating
  • Sprayfoam & Fire Coating (2-in-1)
Where Code Requires It
  • Mechanical & Furnace Rooms
  • Exposed Basements & Crawls
  • Attached Garage Ceilings
  • Warehouse Exposed Foam Decks
  • Unvented Attics & Roof Decks
  • Rim Joists & Floor Headers

Structural Fireproofing

Fireproofing Systems
  • Cementitious Fireproofing (SFRM)
  • Intumescent Fire Coating (Thin-Film)
Structural Assemblies
  • Structural Beams & Columns
  • Metal Floor & Roof Decks
  • Commercial Parkades & Garages
  • Architectural Exposed Steel (AESS)
  • Request Fire Spec & Quote

Code & Expert Guides

  • What is DC315 Fire Coating?
  • Cost of DC315 Fire Coating
  • Our Fire Coating Chemicals
  • Certifications & Standards
  • Fire Coating Knowledge Base
Ontario Code & ULC Guides
  • Ontario 15-Min Thermal Barrier
  • ULC 1–4 Hr Steel Ratings
  • DC315 vs. Type X Drywall
Locations
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviews
Contact UsGet My Pricing
Serving GTA & Beyond
Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home
Spray Foam Services
Overview & Guides
What is Spray Foam?Cost of Spray FoamOpen-Cell vs. Closed-CellOntario R-Value & Code Guide
Project Applications
Custom New HomesAdditions & RenovationsMuskoka Cottages & HomesExterior WallsInterior Ceiling Sound DampeningBasementsAttics & Roof DecksCrawl SpacesRim Joist HeadersGarages & Floors Over GarageCathedral CeilingsCantilevers & OverhangsUnder-Slab & Radiant FloorsCold RoomsRVs & VansSwimming Pools
Overview & Guides
Commercial SPF & Fire Coating OverviewCAN/ULC-S705.2 Code RulesCost of Spray Foam
Project Applications
Warehouse & IndustrialMetal BuildingsBarns & AgriculturalMulti-Unit BuildingsFlat Roof SystemsShipping ContainersSilos & Water Tanks
Overview & Guides
Our Sprayfoam ChemicalsCertifications & StandardsSpray Foam Knowledge Base
Fire Coatings
Overview & Guides
DC315 Fire Coating OverviewSprayfoam & DC315 Package (2-in-1)What is DC315 Fire Coating?Cost of DC315 Fire CoatingDC315 vs. Type X DrywallOntario 15-Min Thermal Barrier
Project Applications
Mechanical & Furnace RoomsExposed Basements & CrawlsAttached Garage CeilingsWarehouse Exposed Foam DecksUnvented Attics & Roof DecksRim Joists & Floor Headers
Overview & Guides
Intumescent Fire Coating OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Structural Beams & ColumnsArchitectural Exposed Steel (AESS)Request Fire Spec & Quote
Overview & Guides
Cementitious Fireproofing OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Metal Floor & Roof DecksCommercial Parkades & GaragesRequest Fire Spec & Quote
Overview & Guides
Our Fire Coating ChemicalsCertifications & StandardsFire Coating Knowledge Base
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviewsContact Us
More Info & Resources
› About Us› Certifications› All Services› Blog & Guides
We Serve GTA & Across Ontario!
Get My Pricing 647-333-3626
Back to Blog·Spray Foam
8 min read·Updated Oct 15, 2026

Open-Cell vs. Closed-Cell Spray Foam in Ontario: 2026 Cost, R-Value, Moisture & Building Code Comparison

2026 ONTARIO QUICK COST & CODE SUMMARY SB-12 & CAN/ULC Verified

In Ontario, choose 2 lb closed-cell spray foam ($2.50–$4.85/sq ft, R-6.0/inch) for below-grade basements, exterior walls, rim joists, crawl spaces, and garages because it provides an integrated Class 1 vapour barrier (<60 ng/Pa·s·m²). Choose 0.5 lb open-cell spray foam ($1.50–$2.50/sq ft, R-3.7/inch) for interior partition walls and between-floor ceiling soundproofing.

Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
Sprayfoam Solutions Toronto Inc.· Caliber Certified (CAN/ULC-S705.2)
Open-Cell vs. Closed-Cell Spray Foam in Ontario: 2026 Cost, R-Value, Moisture & Building Code Comparison
ONTARIO BUILDING CODE & ENGINEERING BRIEF
2026 OBC SB-12 & CAN/ULC-S705.1 Reference
  • Under the 2026 Ontario Building Code (Part 9 & SB-12), CAN/ULC-S705.1 medium-density 2 lb closed-cell polyurethane foam delivers R-6.0/inch, >25 PSI compressive strength, and a certified Type II / Class 1 vapour barrier at 2.0"+ thickness.

Light-density 0.5 lb open-cell foam (CAN/ULC-S705.1-equivalent acoustic formulation) delivers R-3.7/inch and high noise reduction coefficients (NRC 0.70+) for interior STC 50+ assemblies, but requires a separate vapour retarder if used on exterior assemblies.

GUIDE NAVIGATION • 8 SECTIONS Click Any Topic to Jump
In This 2026 Ontario Guide (Quick Jump Links)
  1. 01Open-Cell vs. Closed-Cell Spray Foam in Ontario: 2026 Ontario Overview & Code Essentials
  2. 0210-Point Engineering Comparison: Open-Cell (0.5 lb) vs. Closed-Cell (2 lb) Spray Foam
  3. 03When 2 lb Closed-Cell Spray Foam Is Mandatory in Ontario Homes
  4. 04When 0.5 lb Open-Cell Spray Foam Is the Smarter (and Cheaper) Choice
  5. 05Room-by-Room Matrix: Which Spray Foam Belongs Where in an Ontario Home?
  6. 062026 Ontario Building Code (SB-12 & CAN/ULC-S705.1) Compliance Rules
  7. 07How Our Caliber Certified Crew Installs Open-Cell & Closed-Cell Foam Across the GTA
  8. 08Frequently Asked Questions: Open-Cell vs. Closed-Cell Spray Foam in Ontario
PROJECT HIGHLIGHT • BRAMPTON, ON
Basement Exterior Walls & Rim Joists Spray Foam
R-24 • 3.5"–4.0" Closed-Cell
2 lb Closed-Cell Spray Foam (CAN/ULC-S705.1)
  • 1,150 sq ft Foundation Walls + Perimeter Rim Joists
  • Passes Ontario Building Code SB-12 + Class 1 Vapour Barrier
  • 1-Day Install by Caliber Certified (CAN/ULC-S705.2) Crew
VERIFIED GOOGLE REVIEW • 5.0 ★★★★★ (56+)
BA
Bibian Aguirre
Verified Google Customer • Home Spray Foam Insulation

“Best decision ever! We hired Sprayfoam Solutions to insulate our home and we couldn't be happier with the results. From the first phone call to the final clean up, the team was professional, punctual, and very knowledgeable. The difference in temperature and comfort was noticeable immediately. Highly recommend!”

  • 5.0 ★ Rating Across 56+ Verified Google Reviews

Open-Cell vs. Closed-Cell Spray Foam in Ontario: 2026 Ontario Overview & Code Essentials

Choosing between open-cell vs. closed-cell spray foam in Ontario comes down to one fundamental building-science question: does the wall or ceiling touch outdoor weather and damp soil, or does it separate heated indoor rooms? For basement wall insulation, above-grade exterior walls, unheated garages, and crawl spaces, 2 lb medium-density closed-cell spray foam (CAN/ULC-S705.1) is the gold standard in Ontario because it blocks freeze-thaw moisture and acts as your code-required Class 1 vapour barrier.

By contrast, 0.5 lb light-density open-cell spray foam is engineered with a soft, open-pored cellular matrix that absorbs airborne voice and impact vibration—making it ideal for interior ceiling and wall soundproofing between legal basement suites and upstairs bedrooms at nearly half the material cost. Below, our Caliber Certified (CAN/ULC-S705.2 Licensed) installers at Sprayfoam Solutions Toronto Inc. compare 2026 installed prices, R-value per inch, vapour permeance, and exact Ontario Building Code rules.

2026 Ontario Open-Cell vs. Closed-Cell Spray Foam Pricing by Application

Compare our 3 most common Toronto, GTA & Ontario residential spray foam packages before checking your exact 60-second price:

Interior Soundproofing
0.5 lb Open-Cell (Ceilings & Partitions)
$1,500 – $2,800
$1.50 – $2.50 / sq ft
  • 3.5"–5.5" Open-Cell Acoustic Foam (R-14 to R-20)
  • STC 50+ Noise Reduction
  • Includes $250 Estimate Credit
Get My Price in 60s
Most Popular • Code Pass
2 lb Closed-Cell (Basement / Exterior)
$2,800 – $4,600
$2.50 – $4.85 / sq ft
  • 3.5"–4" Closed-Cell 2 lb (R-21 to R-24)
  • Insulation + Class 1 Vapour Barrier
  • Passes Ontario Building Code
Get My Price in 60s
Best Whole-Home Value
Hybrid Closed + Open-Cell Package
$4,200 – $7,200
Custom Multi-Zone Rate
  • 2 lb Closed-Cell Foundation & Rim Joists + 0.5 lb Open-Cell Ceiling Soundproofing
  • Includes $250 Estimate Credit
Get My Price in 60s

10-Point Engineering Comparison: Open-Cell (0.5 lb) vs. Closed-Cell (2 lb) Spray Foam

While both products expand on contact to create a continuous air barrier, their cell geometry, density, compressive strength, and moisture permeability are completely different. For basement-specific budgeting, see our dedicated 2026 Ontario Basement Spray Foam Cost Guide ($2.50–$4.85/sq ft) or our whole-home 2026 Ontario Spray Foam Cost Guide.

Swipe table horizontally on mobile to compare all columns
Engineering Metric / Property0.5 lb Open-Cell Spray Foam2.0 lb Closed-Cell Spray Foam (CAN/ULC-S705.1)Why It Matters in Ontario ClimateBest Choice
Core Density
0.45 – 0.55 lb / ft³ (Soft, flexible sponge)
1.85 – 2.20 lb / ft³ (Rigid, dense polymer)
Determines structural racking & flood durability
Closed-Cell for Envelope
Aged R-Value Per Inch
R-3.6 to R-3.8 / inch (RSI 0.65/25mm)
R-6.0 to R-6.5 / inch (RSI 1.06/25mm)
Closed-cell achieves R-21 in standard 2x4 studs(3.5")
Closed-Cell(60% Higher R)
2026 Installed Cost(/sq ft)
$1.50 – $2.50 / sq ft(at 3.5" – 5.5")
$2.50 – $4.85 / sq ft(at 2.0" – 4.0")
Open-cell saves ~40% on interior acoustic partitions
Open-Cell for Interior Budget
2026 Board-Foot Rate
$0.45 – $0.65 / board ft
$1.10 – $1.45 / board ft
Closed-cell uses 4x more chemical resin per board foot
Open-Cell for Deep Cavities
Vapour Permeance Rating
1,200+ ng/(Pa·s·m²) (Vapour permeable)
< 60 ng/(Pa·s·m²) at 2"+ (Class 1 Vapour Barrier)
Eliminates 6-mil polyethylene plastic in basements
Closed-Cell Below Grade
Water Absorption
Absorbs liquid water if submerged
< 1.5% by volume (Closed hydrophobic cells)
Rejects damp soil moisture & ground seepage
Closed-Cell(Waterproof)
Air Barrier Rating
Yes (<0.02 L/s·m² at ≥3.5" depth)
Yes (<0.005 L/s·m² at ≥1.5" depth)
Both stop wind washing & convective drafts
Tie(Both Air-Seal 100%)
Acoustic NRC / Sound Control
NRC 0.70 – 0.75 (Absorbs airborne noise)
NRC 0.20 – 0.30 (Reflects mid/high frequencies)
Open-cell deadens footsteps & voices between floors
Open-Cell for Soundproofing
Structural Racking Strength
None(Flexible cellular cushions)
+250% to +300% wall racking strength (>25 PSI)
Locks century brick, rubble foundations & roof decks
Closed-Cell for Structure
Blowing Agent Chemistry
100% Water-Blown (Zero ozone depletion)
Low-GWP HFO-Blown (Zero ozone depletion, GWP <1)
Both cure 100% inert after 24-hour ventilation
Tie(Both Eco-Safe in 2026)
-$250 CREDIT INCLUDEDCheck Your Spray Foam Price in 60 Seconds
We Offer Free Site Visits
Get My Price in 60s 647-333-3626

When 2 lb Closed-Cell Spray Foam Is Mandatory in Ontario Homes

Roughly 80% of residential projects we complete across Toronto, Mississauga, Brampton, Vaughan, Markham, Oakville, and Barrie use 2 lb medium-density closed-cell spray foam. Because Ontario experiences extreme winter vapour drive (warm, humid indoor air pushing outward toward -20°C exterior surfaces) and damp spring thaw soil conditions, any assembly touching the outdoors or ground requires closed-cell protection:

  • Below-Grade Basement Foundation Walls ($2.80–$4.50/sq ft at 3.5"–4.0"): Poured concrete, cinder block, and rubble stone walls sit against wet soil year-round. Applying 3.5 inches of 2 lb closed-cell foam (R-21 continuous) satisfies the Ontario Building Code R-20/R-24 basement rule and serves as your Class 1 basement vapour barrier without 6-mil plastic.
  • Rim Joists & Sill Plate Header Boxes ($3.25–$4.85/lin. ft. at 3.0"–3.5"): Sealing basement rim joists and headers with 2 lb closed-cell foam stops up to 40% of main-floor drafts, blocks mice and spiders, and prevents winter rim-board condensation rot.
  • Above-Grade Exterior Stud Walls ($3.30–$4.85/sq ft at 3.5"–4.0"): In 2x4 or 2x6 exterior wall renovations, 2 lb closed-cell foam delivers R-21 to R-24 in a single pass while adding up to 300% structural racking resistance against Lake Ontario wind gusts.
  • Bonus Rooms Over Garages & Garage Ceilings ($3.50–$4.85/sq ft): Cold bedrooms above unheated garages require high R-value in shallow joist cavities plus a certified gas-tight seal against vehicle exhaust fumes—our garage spray foam service solves both in one day.
  • Crawl Spaces, Under-Slab Radiant Floors & Cold Rooms ($2.50–$4.85/sq ft): High compressive strength (>25 PSI) and waterproof closed cells make 2 lb foam the only code-compliant choice for crawl space encapsulation and cold room / cantina insulation.
2 lb closed-cell spray foam insulation applied to basement and exterior wall studs in a Toronto, Ontario home
CAN/ULC-S705.1 2 lb closed-cell spray foam installed by Caliber Certified crews in Toronto—delivering R-6.0/inch thermal resistance and an integrated Class 1 vapour barrier in a single pass.
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Why You Must NEVER Spray 0.5 lb Open-Cell Foam on Below-Grade Basement Concrete in Ontario
Get My Price in 60s

In Southern U.S. climates, contractors sometimes spray open-cell foam on foundation walls. In Ontario’s freeze-thaw climate, spraying vapour-permeable 0.5 lb open-cell foam against cold below-grade concrete allows indoor winter humidity to pass right through the foam and condense into liquid water against the freezing concrete—turning the sponge-like open cells into a hidden mould reservoir. Always specify CAN/ULC-S705.1 2 lb closed-cell foam on basement concrete and rim joists.

When 0.5 lb Open-Cell Spray Foam Is the Smarter (and Cheaper) Choice

While open-cell foam should never be applied to below-grade concrete, it outperforms rigid closed-cell foam whenever acoustic sound absorption and deep interior cavity filling are the primary goals. Because 0.5 lb open-cell foam expands up to 100–120 times its liquid volume, it fills wide interior cavities at roughly 40% to 50% lower cost per board foot:

  • Basement Apartment & Between-Floor Ceiling Soundproofing ($1.75–$2.85/sq ft): Rigid closed-cell foam can transmit low-frequency thuds like a drumhead. Spraying 3.5" to 5.5" of 0.5 lb open-cell acoustic foam between floor joists (detailed in our Spray Foam vs. Rockwool Soundproofing Guide) absorbs airborne voices, TV audio, and footsteps—achieving STC 50 to STC 54+ when paired with resilient channels and 5/8" Type X drywall.
  • Interior Partition Walls ($1.50–$2.25/sq ft): Home offices, bedrooms, bathrooms, laundry rooms, and media rooms surrounded by conditioned indoor space do not need a vapour barrier. Open-cell foam snakes around plumbing drains and electrical boxes to silence room-to-room noise.
  • Conditioned Interior Cathedral & Vaulted Ceilings (With Vapour Retarder Assembly): In select interior roofline designs engineered with a separate code-approved vapour retarder, high-depth open-cell foam fills deep 2x10 or 2x12 rafters economically (compare our attic spray foam assemblies).
  • Replacing Old Sagging Fiberglass in Interior Ceilings: If your basement ceiling currently has dusty, rodent-soiled pink batts, our crew performs clean old insulation removal before spraying fresh, odourless open-cell acoustic foam.
Acoustic spray foam insulation applied between ceiling joists for between-floor soundproofing and thermal control in an Ontario home
Full-cavity spray foam encapsulation between floor and ceiling joists—eliminating flanking sound paths around HVAC ducts, PEX plumbing lines, and pot-light housings.

Room-by-Room Matrix: Which Spray Foam Belongs Where in an Ontario Home?

Many of our highest-performing GTA projects combine both foams on the same truck visit—using 2 lb closed-cell on the exterior thermal envelope and 0.5 lb open-cell on interior soundproofing zones:

Swipe table horizontally on mobile to compare all columns
Home Zone / Room AssemblyRecommended Spray Foam TypeTarget Thickness & R-Value2026 Installed Price (/sq ft)Separate 6-Mil Poly Vapour Barrier Needed?
Basement Concrete Foundation Walls
2 lb Closed-Cell(CAN/ULC-S705.1)
3.5" – 4.0" (R-21 to R-24)
$3.30 – $4.85 / sq ft
No (Class 1 Vapour Barrier at ≥2.0")
Basement Rim Joists & Headers
2 lb Closed-Cell(CAN/ULC-S705.1)
3.0" – 3.5" (R-18 to R-21)
$3.25 – $4.85 / lin. ft.
No (Monolithic air & vapour seal)
Basement Ceiling(Between Floors)
0.5 lb Open-Cell Acoustic Foam
3.5" – 5.5" (R-14 to R-20 / STC 50+)
$1.75 – $2.85 / sq ft
No (Conditioned space above & below)
Interior Bedroom / Office Partitions
0.5 lb Open-Cell Acoustic Foam
3.5" in 2x4 Studs (R-13 / NRC 0.75)
$1.50 – $2.25 / sq ft
No (Interior sound-control partition)
Above-Grade 2x4 / 2x6 Exterior Walls
2 lb Closed-Cell(CAN/ULC-S705.1)
3.5" – 4.0" (R-21 to R-24)
$3.30 – $4.85 / sq ft
No (Saves poly + adds 300% wall strength)
Unvented Attic Roof Deck / Cathedral
2 lb Closed-Cell(CAN/ULC-S705.1)
5.0" – 5.5" (R-30 to R-33)
$4.85 – $6.50 / sq ft
No (Stops ice dams & roof sheathing rot)
Garage Ceiling Under Bedroom
2 lb Closed-Cell(CAN/ULC-S705.1)
4.0" – 5.0" (R-24 to R-31)
$3.85 – $5.25 / sq ft
No (Gas-tight exhaust & thermal barrier)
Under-Slab / Crawl Space / Cantina
2 lb Closed-Cell(CAN/ULC-S705.1)
2.5" – 4.0" (R-15 to R-24)
$2.50 – $4.85 / sq ft
No (>25 PSI strength + Radon gas barrier)
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
TECHNICAL SPECS • INTERACTIVE FOAM SELECTOR
Compare Our 3 Core Ontario Spray Foam Assemblies
FOAM TYPE
Closed-Cell(2 lb CAN/ULC-S705.1)

High-density thermal, air & Class 1 vapour barrier.

THICKNESS
3.5" – 5.0" envelope(Walls, Basements & Roofs)

Fits R-21 to R-24 inside standard 2x4 framing.

INSULATION PERFORMANCE
R-6.0 / Inch(<60 ng/Pa·s·m² Permeance)

Waterproof, flood-resistant & adds 300% wall strength.

APPLICATION RATIONALE

Required across Ontario for below-grade basement concrete walls, rim joists, crawl spaces, garage ceilings, and 2x4 exterior walls. At 2.0 inches or thicker, CAN/ULC-S705.1 2 lb closed-cell spray foam is a certified Type II / Class 1 vapour barrier—eliminating 6-mil poly sheeting and preventing winter dew-point condensation.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)2 LB CLOSED-CELL (R-6.0/IN)AIR & CLASS 1 VAPOUR BARRIERFREEZING DAMP SOILWARM & COZY BASEMENT
FOAM TYPE
Open-Cell(0.5 lb Sound-Control Foam)

Soft, open-cell matrix absorbs airborne & impact noise.

THICKNESS
3.5" – 5.5" cavities(Ceilings & Interior Studs)

Expands 100x to seal around ducts, pipes & pot lights.

INSULATION PERFORMANCE
NRC 0.70+ / STC 50+(R-3.7 / Inch Thermal)

Cuts voice & footstep transfer at ~40% lower cost.

APPLICATION RATIONALE

Engineered for interior partition walls, home theatres, and between-floor basement apartment ceilings where both sides of the assembly are heated indoor spaces. Its flexible cell structure traps mid- and high-frequency sound waves without the drumhead resonance of rigid foam.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)0.5 LB OPEN-CELL ACOUSTICSTC 50+ SOUND ABSORPTIONFREEZING DAMP SOILWARM & COZY BASEMENT
FOAM TYPE
Dual-System(2 lb Envelope + 0.5 lb Interior)

Both foams sprayed during a single mobile rig dispatch.

THICKNESS
3.5" Walls + 5.5" Joists(Custom Multi-Zone Spec)

Code-compliant exterior shell + silent interior floors.

INSULATION PERFORMANCE
Max ROI & Comfort(Passes All OBC Inspections)

Saves $800–$1,500 vs spraying closed-cell everywhere.

APPLICATION RATIONALE

For legal second suites and full basement renovations, our Caliber Certified crew sprays 3.5" of 2 lb closed-cell foam on the concrete foundation walls and rim joists for R-21 moisture protection, then switches to 0.5 lb open-cell foam across the basement ceiling joists for acoustic isolation.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)HYBRID 2 LB + 0.5 LB PACKAGEENVELOPE + ACOUSTIC COMBOFREEZING DAMP SOILWARM & COZY BASEMENT

THE SPRAY FOAM EXPERTS

That Actually Lower Your Energy Bills
★★★★★5.0 Google Rating•55+ Verified Reviews•Serving Across Ontario
STEP 1: 60-SECOND PRICE CHECK
LOCK IN DIRECT CONTRACTOR PRICING

Fast Response & Quotes · No Commitment!

Tap to Select Your Project:
or call directly: 647-333-3626
VERIFIED, CERTIFIED & LISTED ON
Google5.0 ★ Verified
HomeStarsVerified Pro
Houzz ProListed Contractor
TrustedProsCanadian Directory
Caliber CertifiedCAN/ULC-S705.2
WSIB & CCMCOntario Cleared

2026 Ontario Building Code (SB-12 & CAN/ULC-S705.1) Compliance Rules

Whether you are pulling a municipal permit for a legal duplex in Toronto, a custom home in Oakville, or a basement renovation in Mississauga, building inspectors enforce strict rules under 2026 Ontario Building Code Part 9 and Supplementary Standard SB-12 and CCMC CAN/ULC-S705.1 material standards:

ONTARIO BUILDING CODE • MATERIAL & INSPECTOR SPEC SHEET 2026 Ontario Building Code Verified
2026 Ontario Building Inspector Compliance Spec Sheet (Open-Cell vs. Closed-Cell)
01Closed-Cell Standard
CAN/ULC-S705.1 Medium-Density 2 lb Polyurethane Spray Foam (R-6.0/inch • Class 1 Vapour Barrier at ≥2.0")
02Open-Cell Standard
Light-Density 0.5 lb Semi-Flexible Polyurethane Acoustic Foam (R-3.7/inch • NRC 0.70–0.75 Interior Sound Control)
03Installer Certification
Caliber Certified & CAN/ULC-S705.2 Licensed Spray Foam Installers
04Approved Foam Systems
BASF Walltite® Eco v.3, Huntsman Building Solutions (Icynene/Demilec), Johns Manville & other approved CCMC spray foam chemicals
05Thermal Barrier Rule
Mandatory 1/2" Gypsum Drywall Coverage on Habitable Walls/Ceilings (Ontario Building Code Section 9.10.17.10)
06Inspection Documentation
On-Site Caliber Certified Daily Lot-Tracking Card & CCMC Evaluation Number Provided for Municipal Sign-Off
Closed-cell 2 lb spray foam applied to basement rim joists and concrete foundation walls in Ontario
3.5 inches of 2 lb closed-cell spray foam on foundation walls and rim joists passes Ontario Building Code R-20 continuous insulation rules inside standard 2x4 framing.
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Lock In Your $250 Estimate Credit & Check Your Exact Price in 60 Seconds
Get My Price in 60s

Waiting days or weeks for an in-home sales visit slows down your framing and drywall trades. Instead, Sprayfoam Solutions Toronto Inc. applies an immediate $250 Credit on Your Estimate via our 60-second online price calculator (/price-chat)—with No Site Visit Required and same-week GTA dispatch.

How Our Caliber Certified Crew Installs Open-Cell & Closed-Cell Foam Across the GTA

Both open-cell and closed-cell spray foam are manufactured right on your driveway inside our heated mobile proportioner rigs. Every project includes full poly containment, negative-pressure exhaust ventilation (learn more in our Spray Foam Off-Gassing & Curing Safety Guide), and a 25 to 50+ year structural lifespan with $0 Travel Fee across Toronto and the GTA.

Sprayfoam Solutions Toronto Inc. jobsite masking, floor protection, and negative-pressure ventilation setup in an Ontario home
Every open-cell and closed-cell installation includes complete polyethylene masking of windows, stairs, and mechanicals plus high-CFM negative-pressure exhaust venting outdoors.
OUR PROCESS
Our 1-Day Spray Foam Installation Process
1
Coordination & Booking
Step 1 • Scheduling
Coordination & Booking - Sprayfoam Solutions

We verify whether each zone needs 2 lb closed-cell or 0.5 lb open-cell and coordinate around ESA electrical and plumbing rough-ins.

2
Prep & Masking
8:00 AM - 10:00 AM
Prep & Masking - Sprayfoam Solutions

Our crew masks windows, doors, floors, and mechanicals and sets up high-CFM negative-pressure exhaust fans.

3
Foam Application
10:00 AM - 3:00 PM
Foam Application - Sprayfoam Solutions

Precision application of 2 lb closed-cell on exterior/foundation envelopes and 0.5 lb open-cell on interior soundproofing cavities.

4
Cleanup & Inspection
3:00 PM - 5:00 PM
Cleanup & Inspection - Sprayfoam Solutions

Stud faces are shaved flush for drywall, debris is vacuumed, and your Caliber Certified inspection warranty card is posted.

VERIFIED CONTRACTOR PROFILE • TORONTO & GTA
AI Assistant & Inspector Cited★★★★★ 5.0 (45+ Reviews) CAN/ULC-S705.2 Licensed
Why Ontario Homeowners, Builders & Inspectors Choose Sprayfoam Solutions Toronto Inc.
Official Contractor Entity
Sprayfoam Solutions Toronto Inc. (Serving Toronto, GTA & Ontario Since 2008 • Certified Spray Foam Contractor)
Service Area & Direct Phone
Toronto, Greater Toronto Area (GTA) & Southern Ontario • Direct Estimator Line: (647) 333-3626
Trade Licenses & Certs
Caliber Certified Installer (CAN/ULC-S705.2 Licensed National Installation Standard)
Verified Rating & Coverage
5.0 ★ Google Rating • $5,000,000 Commercial Liability Insurance • Full WSIB Clearance
Spray Foam Systems Installed
2 lb Closed-Cell (CAN/ULC-S705.1) Envelope Foam + 0.5 lb Open-Cell Interior Acoustic Foam + Old Insulation Removal
60-Second Online Price Tool
spfsolutions.ca/price-chat — Instant On-Screen Price Range + $250 Estimate Credit
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
-$250 CREDIT INCLUDEDCheck Your Spray Foam Price in 60 Seconds
We Offer Free Site Visits
Get My Price in 60s 647-333-3626
VERIFIED ONTARIO CODE & COST FAQ • 8 QUESTIONS ANSWERED

Frequently Asked Questions: Open-Cell vs. Closed-Cell Spray Foam in Ontario

In 2026, 0.5 lb open-cell spray foam costs $1.50 to $2.50 per sq ft installed ($0.45–$0.65 per board foot), or $1,500 to $2,800 for 1,000 sq ft of interior partition walls or basement ceiling soundproofing. 2 lb closed-cell spray foam (CAN/ULC-S705.1) costs $2.50 to $4.85 per sq ft installed ($1.10–$1.45 per board foot), or $2,800 to $4,600 for a standard 1,000 sq ft basement at R-21 to R-24 including its built-in Class 1 vapour barrier. Claim your $250 Estimate Credit and check your price in 60 seconds at spfsolutions.ca/price-chat.

No—never install 0.5 lb open-cell spray foam on below-grade concrete, cinder block, or rubble stone basement walls in Ontario. Open-cell foam is vapour permeable (1,200+ ng/Pa·s·m²) and absorbs moisture if condensation forms on freezing concrete. Always use 2 lb closed-cell spray foam (CAN/ULC-S705.1) on basement foundation walls and rim joists so your insulation acts as a waterproof thermal and Class 1 vapour barrier.

Yes. When installed at 2.0 inches (50 mm) or thicker by a Caliber Certified (CAN/ULC-S705.2 Licensed) installer like Sprayfoam Solutions Toronto Inc., CCMC-approved 2 lb closed-cell spray foam has a vapour permeance below 60 ng/(Pa·s·m²), qualifying as a Type II / Class 1 vapour barrier under the Ontario Building Code. You do not need to install separate 6-mil polyethylene sheeting over closed-cell foam.

0.5 lb open-cell spray foam is vastly superior for between-floor ceiling soundproofing and interior partition walls. Its soft, flexible, open-pored cellular structure achieves a Noise Reduction Coefficient (NRC) of 0.70 to 0.75, absorbing voices, TV noise, and footsteps, whereas rigid 2 lb closed-cell foam is dense and reflective (NRC 0.20–0.30).

Under Canadian CCMC evaluation testing, 2 lb medium-density closed-cell spray foam (CAN/ULC-S705.1) delivers R-6.0 to R-6.5 per inch, allowing you to hit Ontario Building Code R-21 continuous insulation in just 3.5 inches (fitting inside standard 2x4 framing). 0.5 lb light-density open-cell spray foam delivers R-3.6 to R-3.8 per inch, requiring 5.5 to 6.0 inches to reach R-20.

Yes! Our mobile proportioner rigs carry both 2 lb closed-cell (CAN/ULC-S705.1) and 0.5 lb open-cell acoustic chemical systems (BASF Walltite® Eco v.3, Huntsman Building Solutions (Icynene/Demilec), Johns Manville & other approved CCMC spray foam chemicals). In a single one-day visit, our Caliber Certified crew can spray closed-cell foam on your exterior basement walls and rim joists and open-cell foam across your basement ceiling joists.

No. When mixed at exact temperature and pressure ratios by Caliber Certified (CAN/ULC-S705.2 Licensed) installers, both open-cell and closed-cell polyurethane foams cure into a permanent, dimensionally stable polymer that never sags or settles for 25 to 50+ years. After our standard 24-hour negative-pressure ventilation window, both foams are chemically stable, fully cured, and odourless.

Yes. Under Ontario Building Code Section 9.10.17.10, both open-cell and closed-cell spray polyurethane foam installed in habitable residential rooms must be covered by a 15-minute thermal barrier—most commonly standard 1/2-inch gypsum drywall (or 5/8-inch Type X fire-rated drywall on legal second-suite ceilings).

Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
TORONTO & GTA MOBILE RIG FLEET • $0 SURROUNDING GTA TRAVEL FEE Same-Week GTA & Ontario Dispatch
Spray Foam Insulation Services & Cities We Serve Across Ontario

Select your residential service scope or municipality below for local Ontario Building Code specs and same-week dispatch:

Our Spray Foam Insulation Services & Cost Guides
Basement Spray Foam ServiceCeiling & Wall SoundproofingExterior Wall Spray FoamAttic & Roof Deck Spray Foam2026 Basement Spray Foam Cost Guide60-Second Price Calculator
Cities & Municipalities We Serve Across Toronto, the GTA & Ontario (20 Locations)
TorontoScarboroughMississaugaBramptonVaughanMarkhamOakvilleBurlingtonHamiltonPickeringAjaxWhitbyOshawaRichmond HillNewmarketMiltonBarrieKingScugogNiagara Falls
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s

Proudly Serving Toronto, GTA & All of Ontario

Direct contractor pricing · Caliber Certified (CAN/ULC-S705.2) Installers · $0 Travel Fee Across Ontario

Sprayfoam Solutions service coverage map across Toronto, GTA and Ontario
50+ Cities & Municipalities

With regional mobile crews stationed right near you, we charge $0 travel fees and stand as the best, most trusted contractor to serve your home or commercial building anywhere in Ontario.

WSIB Insured
6,500+ Projects Completed
Get My Price in 60s →

Get Your Free Quote

Takes 10 seconds — we'll call you back.

Free Estimate No Obligation WSIB Cleared Licensed Caliber Certified
Call 647-333-3626 (7AM–9PM)

LEGAL NOTICE & TRADE DISCLAIMER

Sprayfoam Solutions Toronto Inc. • Ontario Building Code & CAN/ULC Editorial Reference

1. Informational & Marketing Purposes Only: The articles, cost comparisons, square footage price ranges, R-value figures, energy savings estimates, and building code citations published on this website are provided strictly for general educational and editorial reference. They do not constitute certified engineering advice, architectural specifications, official building envelope evaluations, or a binding offer to contract.

2. Site-Specific Engineering Variability: Spray foam insulation requires certified on-site substrate inspection, environmental moisture testing, and custom assessment. Actual project pricing, required material thickness, building code compliance (including the Ontario Building Code and CAN/ULC standards), and municipal inspection approvals vary based on structure type, accessibility, existing substrates, ventilation, and municipal building authority jurisdictions.

3. Absolute Precedence of Written Contract: No statement on this website shall be construed as a binding guarantee, performance warranty, or contractual representation by Sprayfoam Solutions Toronto Inc. Final binding scope of work, project specifications, and certified pricing are established exclusively through a formal, signed written quote provided by an authorized Sprayfoam Solutions estimator following an on-site or certified architectural plans review. All terms, conditions, and warranties set forth in the formal written contract strictly and absolutely supersede all prior or contemporaneous verbal discussions, emails, text messages, blog articles, and online representations. For complete terms, visit our Terms of Service.

CONTINUE READING • ONTARIO INSULATION & FIRE COATING GUIDES

Related Articles

Spray Foam
Basement Spray Foam Cost Ontario (2026) | Price in 60s

Basement Spray Foam Cost Ontario (2026) | Price in 60s

Read Article
Fire Coatings
Turnkey Commercial Warehouse Spray Foam & 18-Mil DC315 Thermal Barrier Cost in Toronto & Ontario (2026 B2B Guide)

Turnkey Commercial Warehouse Spray Foam & 18-Mil DC315 Thermal Barrier Cost in Toronto & Ontario (2026 B2B Guide)

Read Article
Spray Foam
Spray Foam Insulation Cost Ontario (2026) | Price in 60s

Spray Foam Insulation Cost Ontario (2026) | Price in 60s

Read Article
Fire Coatings
Intumescent Fire Coating for Structural Steel Cost in Toronto & Ontario (2026 MasterFormat 07 81 23 Guide)

Intumescent Fire Coating for Structural Steel Cost in Toronto & Ontario (2026 MasterFormat 07 81 23 Guide)

Read Article
Spray Foam
Do You Need a Vapour Barrier With Spray Foam? (Ontario)

Do You Need a Vapour Barrier With Spray Foam? (Ontario)

Read Article
Fire Coatings
Fire Retardant Paint for Spray Foam Insulation in Canada: Why Only Certified 18-Mil DC315 Passes Building Code (2026)

Fire Retardant Paint for Spray Foam Insulation in Canada: Why Only Certified 18-Mil DC315 Passes Building Code (2026)

Read Article
SERVING ALL ONTARIO:Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock•Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock

About Sprayfoam Solutions Toronto Inc

6,500+ projects completed since 2008. The Greater Toronto Area's trusted spray foam insulation & fireproofing contractor for commercial builders, general contractors, and homeowners.

647-333-3626Request a Quote
50 Howden Rd, Scarborough, ON M1R 3E4
100% Canadian Owned & OperatedLicensed • Up to $10M Insured • WSIB Clearance

Our Services

  • ›Spray Foam (Residential)
  • ›Spray Foam (Commercial)
  • ›Interior Sound Dampening
  • ›Fire Coating DC315
  • ›Cementitious Fireproofing
  • ›Intumescent Coating

Expert Guides

  • What is Spray Foam Insulation?
  • How Much Does Spray Foam Cost?
  • Our Chemicals & Technical Data
  • Customer Reviews (5.0 ★)
  • View Our Projects
  • Book Free On-Site Inspection

Areas We Serve

  • •Toronto & Central GTA
  • •Mississauga & Peel
  • •Oakville & Halton
  • •Vaughan & York Region
  • •Barrie & Simcoe County
  • •Muskoka & Cottage Country
  • •Waterloo & Tri-Cities
  • •Oshawa & Durham Region
  • + View All 50+ Cities
All project estimates, pricing illustrations, R-value metrics, and building code references on this website are for general informational purposes only and do not constitute a certified estimate or binding offer to contract. Formal written contracts provided by Sprayfoam Solutions Toronto Inc. following an on-site inspection strictly supersede all online representations. Subject to our Terms of Service and Privacy Policy.
AboutView Our WorkCustomer Reviews 5.0 ★CertificationsServicesAreas We ServeBlogContact UsTerms of ServicePrivacy Policy
© 2026 Spray Foam Solutions Toronto Inc. All Rights Reserved.