Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home

Residential

Major Projects
  • Custom New Homes
  • Additions & Renovations
  • Muskoka Cottages & Homes
  • Exterior Walls
  • Interior Ceiling Sound Dampening
Targeted Areas
  • Basements
  • Attics & Roof Decks
  • Crawl Spaces
  • Rim Joist Headers
  • Garages & Floors Over Garage
  • Cathedral Ceilings
  • Cantilevers & Overhangs
  • Under-Slab & Radiant Floors
  • Cold Rooms
  • RVs & Vans
  • Swimming Pools

Commercial

Buildings & Facilities
  • Commercial SPF & Fire Coating
  • Warehouse & Industrial
  • Metal Buildings
  • Barns & Agricultural
  • Multi-Unit Buildings
  • Flat Roof Systems
Specialty
  • Shipping Containers
  • Silos & Water Tanks

Code & Expert Guides

  • What is Spray Foam?
  • Cost of Spray Foam
  • Our Sprayfoam Chemicals
  • Certifications & Standards
  • Spray Foam Knowledge Base
Ontario Code & ULC Guides
  • Ontario R-Value & Code Guide
  • CAN/ULC-S705.2 Code Rules
  • Open-Cell vs. Closed-Cell

Thermal Barriers (Foam)

Core Systems
  • DC315 Intumescent Coating
  • Sprayfoam & Fire Coating (2-in-1)
Where Code Requires It
  • Mechanical & Furnace Rooms
  • Exposed Basements & Crawls
  • Attached Garage Ceilings
  • Warehouse Exposed Foam Decks
  • Unvented Attics & Roof Decks
  • Rim Joists & Floor Headers

Structural Fireproofing

Fireproofing Systems
  • Cementitious Fireproofing (SFRM)
  • Intumescent Fire Coating (Thin-Film)
Structural Assemblies
  • Structural Beams & Columns
  • Metal Floor & Roof Decks
  • Commercial Parkades & Garages
  • Architectural Exposed Steel (AESS)
  • Request Fire Spec & Quote

Code & Expert Guides

  • What is DC315 Fire Coating?
  • Cost of DC315 Fire Coating
  • Our Fire Coating Chemicals
  • Certifications & Standards
  • Fire Coating Knowledge Base
Ontario Code & ULC Guides
  • Ontario 15-Min Thermal Barrier
  • ULC 1–4 Hr Steel Ratings
  • DC315 vs. Type X Drywall
Locations
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviews
Contact UsGet My Pricing
Serving GTA & Beyond
Sprayfoam Solutions Toronto Inc.
Home
Spray Foam Services
Overview & Guides
What is Spray Foam?Cost of Spray FoamOpen-Cell vs. Closed-CellOntario R-Value & Code Guide
Project Applications
Custom New HomesAdditions & RenovationsMuskoka Cottages & HomesExterior WallsInterior Ceiling Sound DampeningBasementsAttics & Roof DecksCrawl SpacesRim Joist HeadersGarages & Floors Over GarageCathedral CeilingsCantilevers & OverhangsUnder-Slab & Radiant FloorsCold RoomsRVs & VansSwimming Pools
Overview & Guides
Commercial SPF & Fire Coating OverviewCAN/ULC-S705.2 Code RulesCost of Spray Foam
Project Applications
Warehouse & IndustrialMetal BuildingsBarns & AgriculturalMulti-Unit BuildingsFlat Roof SystemsShipping ContainersSilos & Water Tanks
Overview & Guides
Our Sprayfoam ChemicalsCertifications & StandardsSpray Foam Knowledge Base
Fire Coatings
Overview & Guides
DC315 Fire Coating OverviewSprayfoam & DC315 Package (2-in-1)What is DC315 Fire Coating?Cost of DC315 Fire CoatingDC315 vs. Type X DrywallOntario 15-Min Thermal Barrier
Project Applications
Mechanical & Furnace RoomsExposed Basements & CrawlsAttached Garage CeilingsWarehouse Exposed Foam DecksUnvented Attics & Roof DecksRim Joists & Floor Headers
Overview & Guides
Intumescent Fire Coating OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Structural Beams & ColumnsArchitectural Exposed Steel (AESS)Request Fire Spec & Quote
Overview & Guides
Cementitious Fireproofing OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Metal Floor & Roof DecksCommercial Parkades & GaragesRequest Fire Spec & Quote
Overview & Guides
Our Fire Coating ChemicalsCertifications & StandardsFire Coating Knowledge Base
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviewsContact Us
More Info & Resources
› About Us› Certifications› All Services› Blog & Guides
We Serve GTA & Across Ontario!
Get My Pricing 647-333-3626
Back to Blog·Fire Coatings
11 min read·Updated Oct 23, 2026

ULC Fire-Rated Design Numbers Explained for Ontario Structural Steel & Decks (2026 CAN/ULC-S101 F900, D900 & Z600 Spec Guide)

2026 ONTARIO QUICK COST & CODE SUMMARY SB-12 & CAN/ULC Verified

In Ontario commercial construction, ULC Fire-Rated Design Numbers (Z600 columns, F900/D900 floor-ceiling and roof-ceiling assemblies, O900 beams) dictate the exact thickness of cementitious fireproofing (SFRM) ($2.25–$5.85/sq ft) or intumescent fire coating ($5.50–$10.50/sq ft) required under CAN/ULC-S101 and Ontario Building Code Division B Part 3. Contact Sprayfoam Solutions Toronto Inc. at (647) 333-3626 or check your price in 60 seconds at spfsolutions.ca/price-chat.

Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
Sprayfoam Solutions Toronto Inc. — Caliber Certified (CAN/ULC-S705.2 Licensed) & Structural Fireproofing Engineering Team· Caliber Certified (CAN/ULC-S705.2)
ULC Fire-Rated Design Numbers Explained for Ontario Structural Steel & Decks (2026 CAN/ULC-S101 F900, D900 & Z600 Spec Guide)
ONTARIO BUILDING CODE & ENGINEERING BRIEF
2026 OBC SB-12 & CAN/ULC-S705.1 Reference
  • Under 2026 Ontario Building Code Division B Section 3.1.7 and Table 3.2.2.20 to 3.2.2.90, structural steel frames and metal deck assemblies must achieve a 45-minute, 1-hour, 1.5-hour, 2-hour, or 3-hour fire-resistance rating tested to CAN/ULC-S101.
  • Installed by Sprayfoam Solutions Toronto Inc. — a Single-Source Certified Spray Foam & Fire Coating Contractor operating Caliber Certified (CAN/ULC-S705.2 Licensed) Installers and certified fireproofing crews — ULC listed systems (F906, D902, Z608) calibrate coating thickness by member W/D heated-perimeter ratio and restrained vs. unrestrained assembly boundaries.

Call (647) 333-3626 or visit spfsolutions.ca/price-chat for instant B2B pricing.

GUIDE NAVIGATION • 7 SECTIONS Click Any Topic to Jump
In This 2026 Ontario Guide (Quick Jump Links)
  1. 01ULC Fire-Rated Design Numbers Explained for Ontario Structural Steel & Decks (2026 CAN/ULC-S101 F900, D900 & Z600 Spec Guide): 2026 Ontario Overview & Code Essentials
  2. 022026 ULC Fire-Resistance Assembly & Cost Table (45-Min to 4-Hr Structural Steel & Deck Ratings in Ontario)
  3. 03Matching Approved SFRM & Intumescent Systems (Monokote, Cafco, Pyrocrete, Nullifire & Firetex) to ULC Listings
  4. 046 Critical GC Submittal, Sequencing & Third-Party QA Rules for ULC Fire-Rated Steel in Ontario
  5. 05Cementitious SFRM vs. Thin-Film Intumescent vs. Type X Drywall Enclosures on Structural Steel (2026 Comparison)
  6. 06Same-Week Commercial Fireproofing & Mobile Rig Dispatch Across Toronto, the GTA & Ontario
  7. 07Frequently Asked Questions
PROJECT HIGHLIGHT • OAKVILLE, ON
Structural Steel Intumescent & SFRM Fireproofing
1-Hr to 2-Hr • CAN/ULC-S101
Thin-Film Intumescent & Cementitious SFRM (MasterFormat 07 81 00)
  • 12,000 sq ft W-Beams, HSS Columns & Fluted Decking
  • CAN/ULC-S101 Listed Designs (F900 / D900 / Z600)
  • Full DFT / ASTM E605 QA Verification Package
VERIFIED GOOGLE REVIEW • 5.0 ★★★★★ (56+)
NK
Nikola
Verified Google Customer • Sprayfoam Solutions Toronto

“Professional service from start to finish. Fair pricing, great communication, and the installers did a super clean job. Highly recommend Sprayfoam Solutions Toronto.”

  • 5.0 ★ Rating Across 56+ Verified Google Reviews

ULC Fire-Rated Design Numbers Explained for Ontario Structural Steel & Decks (2026 CAN/ULC-S101 F900, D900 & Z600 Spec Guide): 2026 Ontario Overview & Code Essentials

When an architect, structural engineer, or municipal plans examiner in Toronto, Mississauga, Brampton, Vaughan, Hamilton, or Ottawa reviews a Part 3 commercial building permit, specifying "1-hour or 2-hour fireproofing on structural steel" on the general notes sheet is never sufficient for occupancy sign-off. Under Ontario Building Code Division B Section 3.1.7 (Fire-Resistance Ratings) and CAN/ULC-S101 (Standard Methods of Fire Endurance Tests of Building Construction and Materials), every protected steel column, wide-flange girder, open-web steel joist (OWSJ), and fluted composite concrete floor deck must reference an exact Underwriters Laboratories of Canada (ULC) Fire-Rated Design Number—such as ULC Design No. F906, ULC Design No. D902, ULC Design No. Z608, or ULC Design No. O905—and be installed by a qualified cementitious fireproofing and intumescent fire coating contractor.

At Sprayfoam Solutions Toronto Inc., we serve Ontario general contractors, steel fabricators, and industrial developers as a Single-Source Certified Spray Foam & Fire Coating Contractor with Caliber Certified (CAN/ULC-S705.2 Licensed) Installers and specialized Division 07 fireproofing crews. Whether your project requires pumping standard or medium-density cementitious Spray-Applied Fire-Resistive Materials (SFRM) across a multi-storey steel deck, spraying architectural thin-film intumescent coatings onto exposed W-shapes and HSS columns, or coordinating a Turnkey 2 lb Closed-Cell Spray Foam + 18-Mil DC315 Thermal Barrier Package with IFTI DC315 fire coating at the exterior envelope transition, decoding ULC design numbers before tender close prevents five-figure change orders. Get a $250 Credit on Your Estimate — Check Your Price in 60 Seconds (/price-chat) • No Site Visit Required, or send your structural steel schedule and architectural fire matrix to our General Contractor & B2B Estimating Desk.

2026 Ontario ULC Structural Fireproofing & Fire Coating Cost by B2B Project Tier

Compare our 3 commercial B2B volume pricing tiers for CAN/ULC-S101 cementitious SFRM, intumescent steel coatings, and thermal barrier transitions across the GTA & Ontario:

Small Structural Steel / Tenant Fit-Out Scope
1,000 – 4,000 Sq Ft Steel & Deck Area
$4,800 – $22,500
$3.50 – $10.50 / sq ft installed
  • 45-Min to 2-Hr CAN/ULC-S101 Rating (Cementitious SFRM Patch/Respray or Intumescent Beams/Columns)
  • ASTM E605/E736 & DFT QA Log
  • Includes $250 Estimate Credit
Get My Price in 60s
Most Popular • Mid-Size Commercial Steel Package
5,000 – 20,000 Sq Ft Steel & Deck Area
$16,250 – $115,000
$2.75 – $7.85 / sq ft installed
  • 1-Hr to 2-Hr ULC F900 / D900 / Z600 Assemblies (Monokote MK-6 / Z-106, Cafco 300 / 400 or Nullifire / Firetex Intumescent)
  • Full W/D Takeoff & Inspector Submittal Binder
Get My Price in 60s
Large Industrial, Parkade & Multi-Storey Structure
20,000 – 75,000+ Sq Ft Steel & Deck Area
$45,000 – $340,000+
$2.25 – $6.40 / sq ft installed
  • High-Production Continuous Mixer-Pump SFRM + 3,000 PSI Airless Intumescent & Turnkey SPF/DC315 Envelope Tie-Ins
  • Third-Party Testing Coordination
  • Priority GC Pricing
Get My Price in 60s

2026 ULC Fire-Resistance Assembly & Cost Table (45-Min to 4-Hr Structural Steel & Deck Ratings in Ontario)

In 2026, installed commercial pricing for CAN/ULC-S101 structural steel fireproofing in Ontario ranges from $2.25 to $5.85 per square foot for cementitious fireproofing (SFRM) (MasterFormat 07 81 16) and $5.50 to $10.50+ per square foot for thin-film intumescent fire coatings (MasterFormat 07 81 23), while 18-mil IFTI DC315 thermal barrier coating over spray foam (CAN/ULC-S124) averages $1.75 to $3.25 per sq ft. The exact thickness and square-foot cost depend on the specified ULC Design Number, the required hourly fire-resistance rating (45 min, 1 hr, 1.5 hr, 2 hr, 3 hr, or 4 hr), and each steel member’s Weight-to-Heated-Perimeter (W/D or M/D) ratio:

Swipe table horizontally on mobile to compare all columns
ULC Design Series & Structural ElementCommon Ontario ULC Design NumbersApproved Fireproofing System & Thickness Range2026 Installed Rate (/sq ft)Typical Commercial Project Total
F900 Series — Unprotected Concrete/Steel Deck + Protected Beams/Joists
ULC F906, ULC F901, ULC F910, ULC F912(1-Hr to 2-Hr Restrained/Unrestrained)
15 lb Standard SFRM (Monokote MK-6 / Cafco 300) at 3/8" to 1-1/8" on beams/OWSJ
$2.25 – $4.10 / sq ft
$13,500 – $61,500(6,000–15,000 sq ft)
D900 Series — Protected Fluted Steel Floor/Roof Deck + Beams
ULC D902, ULC D907, ULC D916, ULC D925(1-Hr to 3-Hr Composite Deck)
15 lb–22 lb SFRM (MK-6 / Z-106 / Cafco 300/400) at 1/2" to 1-3/4" across deck & beams
$2.65 – $5.25 / sq ft
$26,500 – $131,250(10,000–25,000 sq ft)
Z600 Series — Structural Steel Columns(Wide-Flange & HSS Tubes)
ULC Z601, ULC Z608, ULC Z611, ULC Z623(1-Hr to 4-Hr W-Shapes & HSS)
22 lb–40 lb Medium/High-Density SFRM (Z-106 / Cafco 400 / Pyrocrete) at 1/2" to 2-1/4"
$3.40 – $5.85 / sq ft
$10,200 – $46,800(3,000–8,000 sq ft)
Z600 / O900 Architectural — Exposed Steel Intumescent Mastic
ULC Z619, ULC Z629, ULC O905, ULC F914(45-Min to 2-Hr Exposed AESS)
Thin-Film Intumescent (Nullifire SC902 / Firetex / SprayFilm) at 30–145 Mils DFT
$5.50 – $10.50 / sq ft
$16,500 – $84,000(3,000–8,000 sq ft)
CAN/ULC-S124 Envelope Tie-In — Spray Foam Thermal Barrier
CCMC #14036-R / CAN/ULC-S124(15-Min OBC 3.1.4.2 Thermal Barrier Over SPF)
18 Mils WFT (12 Mils DFT) IFTI DC315® over 2.0" – 3.5" 2 lb Closed-Cell SPF
$4.25 – $7.50 / sq ft(Turnkey SPF+DC315)
$21,250 – $90,000(5,000–12,000 sq ft)
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s

Decoding ULC Fire-Resistance Design Number Prefixes (F, D, Z, O, W, I & P Series Explained)

In the UL Product iQ / ULC Online Directories and the National Building Code / Ontario Building Code Division B Appendix D, every fire-resistance design number begins with an alphabetical prefix that identifies the exact structural assembly type and test geometry, followed by a three-digit series code indicating the protection category (900-series and 600-series typically denote spray-applied cementitious or intumescent coatings directly applied to steel without a suspended lath-and-plaster ceiling):

Swipe table horizontally on mobile to compare all columns
ULC Prefix LetterStructural Assembly Category (CAN/ULC-S101)What the 600 / 700 / 800 / 900 Number Series Means on Ontario BlueprintsCommon Examples & Field Application
D Series(D700, D800, D900)
Floor-Ceiling Assemblies(Steel Framing)
Concrete topping over fluted steel floor deck supported by steel beams/joists. D900 = direct spray-applied fireproofing without a rated suspended acoustic ceiling.
ULC D902 / ULC D907: SFRM sprayed onto steel beams and underside of fluted deck when normal-weight concrete topping requires deck protection.
F Series(F800, F900)
Floor-Ceiling Assemblies(Unprotected Deck Option)
Composite or non-composite concrete slab over steel deck where concrete depth (≥65 mm–115 mm) satisfies the slab rating, requiring SFRM only on supporting steel beams/joists.
ULC F906: One of Ontario’s most common specs—saves thousands by leaving the galvanized steel pan bare while spraying only the structural beams/OWSJ.
P Series(P700, P800, P900)
Roof-Ceiling Assemblies(Insulated Roof Decks)
Corrugated steel roof deck with rigid roof board or membrane above and direct-applied SFRM or intumescent coating below on joists and deck flutes.
ULC P902 / ULC P921: Commercial retail plazas, schools, and industrial plants requiring a 45-min or 1-hr fire-rated roof assembly.
Z Series(Z600, Z700, Z800)
Structural Steel Columns(Wide-Flange & HSS)
Vertical load-bearing columns heated on all 4 sides during CAN/ULC-S101 furnace testing. Z600 = contour-sprayed cementitious or intumescent coatings.
ULC Z601 / ULC Z608 / ULC Z619: Wide-flange W-columns and hollow structural steel (HSS square/round tubes) in parkades, lobbies, and warehouses.
O Series(O800, O900)
Individual Structural Steel Beams & Girders
Stand-alone steel transfer beams, spandrel girders, and mezzanine beams evaluated independently of the floor deck assembly above.
ULC O905 / ULC O909: Transfer girders and structural lintels requiring 1-hr to 3-hr contour protection with SFRM or intumescent mastic.
W & I Series(W400, I500)
Walls, Partitions & Precast Concrete Slabs
Fire-rated steel-stud demising walls (W-series) and hollow-core or precast concrete floor units (I-series / J-series) tying into structural steel frames.
ULC W404 / ULC W415: Rated shaft walls and fire separations where fireproofing must maintain continuity across structural steel penetrations.
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
Rough-textured cementitious fireproofing (SFRM) applied to structural steel I-beams and corrugated metal decking in Brampton (Castlemore & Credit Valley) [JOB-2026-03-09-01]
Commercial ULC F900/D900 assembly in Brampton (Castlemore & Credit Valley): High-bond rough-textured cementitious fireproofing sprayed over commercial structural steel and decking — verified to ASTM E605 thickness/density and ASTM E736 bond standards [JOB-2026-03-09-01].

Restrained vs. Unrestrained Beam & Assembly Ratings in CAN/ULC-S101 (Why It Changes Your Coating Thickness by 30%–50%)

One of the costliest mistakes general contractors and estimators make when pricing a ULC D902 or ULC F906 specification is confusing Restrained Assembly / Restrained Beam ratings with Unrestrained Assembly / Unrestrained Beam ratings. During a fire, structural steel loses approximately 50% of its yield strength at 538°C (1,000°F) (CAN/ULC-S101 critical temperature criteria). When a steel beam is welded or shear-connected to a heavy cast-in-place concrete floor slab and surrounded by rigid structural bays that resist thermal expansion, rotational thermal stresses are absorbed by the surrounding frame (Restrained). Conversely, simple-span roof joists, cantilevers, or light framing that can expand freely must support the dead load purely through the steel’s own flexural capacity (Unrestrained):

  • 1. Restrained Beam Thickness Savings (Typically 3/8" to 5/8" SFRM for 1–2 Hr): In a standard composite concrete-over-metal-deck floor (ULC F906 or ULC D902), if the engineer of record confirms the steel framing is thermally Restrained, a W250x49 (W10x33) wide-flange beam (W/D = 0.84) typically requires only 9.5 mm (3/8") to 13 mm (1/2") of standard cementitious fireproofing for a 1-hour to 2-hour rating.
  • 2. Unrestrained Beam Thickness Escalation (Often 3/4" to 1-3/8"+ SFRM): If that exact same beam is classified as Unrestrained—which is common in open-web steel joist (OWSJ) roof assemblies, mechanical penthouses, or non-composite retrofits—the required CAN/ULC-S101 limiting steel temperature drops significantly, increasing the required SFRM thickness by 30% to 55% (or adding 30 to 65 mils DFT of intumescent paint).
  • 3. How W/D (Weight-to-Heated-Perimeter) & M/D Ratios Drive Material Takeoff: Heavy stocky columns (such as W360x196 with a high W/D ratio of 2.15) act as a massive thermal heat sink and require far thinner fireproofing than slender light sections (W200x36, W/D = 0.69) or thin-wall HSS hollow tubes (C/D ratio). Our commercial estimating team calculates the exact W/D ratio for every steel mark on your structural framing plan so you never over-buy chemical or fail a third-party pin-depth audit.
  • 4. Open-Web Steel Joists (OWSJ) Minimum Chord & Web Sizing Rules: Many ULC roof and floor designs (ULC F906, ULC P902) base their standard SFRM or intumescent thickness on a minimum structural joist size (e.g., 10K1 or minimum web rod diameter). Undersized light joists require increased thickness adjustments per the ULC design footnotes.

Matching Approved SFRM & Intumescent Systems (Monokote, Cafco, Pyrocrete, Nullifire & Firetex) to ULC Listings

Under Ontario Building Code Division B Part 3, a ULC design number is not a generic permission slip to apply any brand of plaster or fire paint at an arbitrary depth. Every ULC design listing explicitly names the tested manufacturer product code and required minimum density. As a certified Division 07 fireproofing contractor, Sprayfoam Solutions Toronto Inc. installs and certifies Isolatek Cafco® 300, GCP Monokote® MK-6® / Z-106, Carboline Pyrocrete® / Nullifire® SC902, Sherwin-Williams Firetex® & other ULC-listed structural fireproofing systems:

ONTARIO BUILDING CODE PART 3 • CAN/ULC-S101 & S124 ENGINEERING SPECS 2026 Ontario Building Code Verified
Approved Structural Fireproofing & Thermal Barrier Systems Installed by Sprayfoam Solutions Toronto Inc. (2026)
01Standard-Density SFRM (15 lb/ft³)
GCP Monokote® MK-6® HY / MK-6s & Isolatek Cafco® 300 / Cafco® 300 SB (Gypsum/Vermiculite — Concealed Beams, Joists & Decks • ASTM E605 ≥15 pcf • ASTM E736 ≥200 psf Bond)
02Medium & High-Density SFRM (22–40 lb/ft³)
GCP Monokote® Z-106 / Z-146, Isolatek Cafco® 400 / Fendolite® MII & Carboline Pyrocrete® 241 (Portland Cement — Parkades, Mech Rooms & High-Abrasion Zones • ≥430–1,000+ psf Bond)
03ULC-Listed Structural Umbrella (BM-44C)
Isolatek Cafco® 300, GCP Monokote® MK-6® / Z-106, Carboline Pyrocrete® / Nullifire® SC902, Sherwin-Williams Firetex® & other ULC-listed structural fireproofing systems
04CAN/ULC-S124 Foam Thermal Barrier (BM-44B)
IFTI DC315® (CCMC #14036-R), No-Burn® Plus ThB, Flame Control No. 60-60A & other approved CAN/ULC-S124 thermal barrier coatings (18 Mils WFT / 12 Mils DFT over SPF)
05CAN/ULC-S705.1 Spray Foam Umbrella (BM-44A)
BASF Walltite® Eco v.3, Huntsman Building Solutions (Icynene/Demilec), Johns Manville & other approved CCMC spray foam chemicals (Installed by Caliber Certified Installers)
06Testing & QA Verification Standards
CAN/ULC-S101 (Fire Endurance), CAN/ULC-S102 (Flame Spread), ASTM E605 (Thickness & Density), ASTM E736 (Cohesion/Adhesion) & SSPC-PA 2 Calibrated Elcometer DFT Logs

When to Specify Standard 15 lb Gypsum SFRM vs. 22–40 lb Portland Cement SFRM vs. Thin-Film Intumescent Coating

Selecting the right material class within a ULC design family (F900, D900, or Z600) protects both your construction budget and long-term facility durability. While 15 lb/ft³ gypsum-based SFRM (Monokote MK-6 / Cafco 300) is the lowest-cost solution ($2.25–$4.10/sq ft) for concealed floor plenums above drop ceilings, Ontario building officials and project specifications mandate 22 lb/ft³ medium-density (Monokote Z-106 / Cafco 400) or 40 lb/ft³ high-density Portland cement SFRM (Monokote Z-146 / Pyrocrete 241) in unconditioned underground parkades, loading docks, elevator shafts, and mechanical rooms exposed to humidity, freeze-thaw cycles, or air velocities above 4.0 m/s. Where structural steel remains architecturally exposed to view (AESS lobbies, retail showrooms, offices, or gym mezzanines), intumescent fire coating provides a smooth, paint-like finish at 30 to 145 mils DFT without bulky fibrous texture.

Clear Sansin Firestop 99 intumescent fire coating applied to high-quality pressurized mass timber walls and ceilings in Vaughan (Kleinburg & Woodbridge) [JOB-2026-07-24-01]
Low-VOC clear intumescent finish in Vaughan (Kleinburg & Woodbridge): High-quality pressurized timber ceiling and wall panels protected with clear, see-through Sansin Firestop 99 intumescent fire coating for ULC Fire-Rated Design Numbers Explained for Ontario Structural Steel & Decks [JOB-2026-07-24-01].

Crucial Code Distinction: CAN/ULC-S101 Structural Steel Fireproofing vs. CAN/ULC-S124 (IFTI DC315) Spray Foam Thermal Barrier

On commercial warehouses, underground parkade soffits, and mixed-use buildings across the GTA, general contractors frequently need both structural steel fire-resistance (CAN/ULC-S101) and spray polyurethane foam thermal barrier protection (CAN/ULC-S124) under the same roof. Evaluated by the Canadian Construction Materials Centre (CCMC #14036-R), IFTI DC315 thermal barrier coating (18 mils WFT / 12 mils DFT) satisfies OBC Section 3.1.4.2 as a 15-minute thermal barrier over 2 lb closed-cell spray foam (see our Turnkey Warehouse Spray Foam + DC315 Guide and Commercial Warehouse Insulation Cost Guide). However, DC315 cannot be substituted for a 1-hour or 2-hour ULC Z600/F900 structural steel rating—and conversely, pumping wet cementitious SFRM directly over closed-cell spray foam violates ULC substrate adhesion rules unless engineered mechanical lath is installed. Because Sprayfoam Solutions Toronto Inc. operates both Caliber Certified (CAN/ULC-S705.2 Licensed) Installers and certified structural fireproofing crews, we sequence the ULC-S101 steel fireproofing before spraying the CAN/ULC-S705.1 foam and 18-mil DC315 envelope.

TECHNICAL SPECS • 3 CORE ULC FIREPROOFING & ENVELOPE ASSEMBLIES
Explore Our ULC-Listed Structural Steel & Thermal Barrier Systems
SYSTEM / COATING TYPE
Cementitious SFRM(Monokote MK-6 / Z-106 • Cafco 300 / 400)

15 lb standard gypsum or 22–40 lb Portland cement SFRM.

REQUIRED THICKNESS
3/8" – 2-1/4" Pass(Calibrated by W/D Ratio)

Verified via ASTM E605 pin-depth & core density discs.

CODE & FIRE PERFORMANCE
1-Hr to 4-Hr ULC(CAN/ULC-S101 Listed)

Protects steel beams, columns, OWSJ & fluted decks.

APPLICATION RATIONALE

Ideal for concealed floor-ceiling plenums (ULC F906, D902), mechanical rooms, and underground parkades (Monokote Z-106 / Cafco 400). Pumped at high production rates to lock in 45-minute to 4-hour CAN/ULC-S101 structural fire endurance at the lowest cost per square foot.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)ULC F906 / D902 / Z608 SFRM1-HR TO 4-HR CAN/ULC-S101 RATINGFREEZING DAMP SOILWARM & COZY BASEMENT
SYSTEM / COATING TYPE
Thin-Film Intumescent(Nullifire SC902 • Firetex • SprayFilm)

Architectural smooth finish for exposed AESS steel.

REQUIRED THICKNESS
30 – 145 Mils DFT(Dry Film Thickness)

Applied via 3,000+ PSI airless rig over compatible primer.

CODE & FIRE PERFORMANCE
45-Min to 3-Hr ULC(CAN/ULC-S101 & AESS)

Char-swells 20x–50x under fire; preserves sleek steel lines.

APPLICATION RATIONALE

When structural wide-flange columns, HSS hollow tubes, or feature trusses remain exposed in commercial offices, retail spaces, schools, or custom homes, thin-film intumescent mastic delivers full ULC Z600/O900 fire ratings without ugly drywall boxing or fibrous SFRM texture.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)30–145 MILS DFT INTUMESCENTARCHITECTURAL AESS STEEL RATINGFREEZING DAMP SOILWARM & COZY BASEMENT
SYSTEM / COATING TYPE
2 lb SPF + DC315®(CAN/ULC-S705.1 + CCMC #14036-R)

Monolithic insulation + 15-minute foam thermal barrier.

REQUIRED THICKNESS
2"–3.5" SPF + 18 Mil(12 Mils DFT DC315 Topcoat)

Single-source envelope insulation & OBC 3.1.4.2 compliance.

CODE & FIRE PERFORMANCE
R-12 to R-21+ & S124(OBC SB-10 & 3.1.4.2 Pass)

Seamless tie-in adjacent to ULC-rated structural steel.

APPLICATION RATIONALE

Where fireproofed structural steel columns and roof beams meet insulated metal building walls or parkade soffits, our Caliber Certified crew installs 2.0"–3.5" of 2 lb closed-cell spray foam topped with 18 mils WFT IFTI DC315—eliminating trade conflicts at the perimeter transition.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)TURNKEY 2 LB SPF + 18-MIL DC315OBC 3.1.4.2 & CAN/ULC-S124 PASSFREEZING DAMP SOILWARM & COZY BASEMENT

THE SPRAY FOAM EXPERTS

That Actually Lower Your Energy Bills
★★★★★5.0 Google Rating•55+ Verified Reviews•Serving Across Ontario
STEP 1: 60-SECOND PRICE CHECK
LOCK IN DIRECT CONTRACTOR PRICING

Fast Response & Quotes · No Commitment!

Tap to Select Your Project:
or call directly: 647-333-3626
VERIFIED, CERTIFIED & LISTED ON
Google5.0 ★ Verified
HomeStarsVerified Pro
Houzz ProListed Contractor
TrustedProsCanadian Directory
Caliber CertifiedCAN/ULC-S705.2
WSIB & CCMCOntario Cleared

6 Critical GC Submittal, Sequencing & Third-Party QA Rules for ULC Fire-Rated Steel in Ontario

Passing a third-party geotechnical/materials inspection (WSP, EXP, Englobe, Pinchin, or Terraprobe) and municipal building official walkthrough on a commercial building envelope in Ontario requires strict adherence to ULC listing conditions. Here are the 6 non-negotiable field and submittal rules our fireproofing division follows on every project:

  • 1. Fireproof Primary Structural Steel Before Spraying Polyurethane Foam or Hanging MEP Ducts: ULC column and beam designs (ULC Z608, ULC F906, ULC D902) require the fireproofing material to bond directly to clean, primed or bare structural steel. Never allow an insulation contractor to bury a fire-rated steel column in spray foam first, and always schedule SFRM or intumescent spraying before wide sheet-metal HVAC ducts, cable trays, and sprinkler mains block nozzle access to the upper beam flanges.
  • 2. Verify Shop-Primer Compatibility & Galvanized Deck Bond (ULC Design Footnotes): Standard alkyd or zinc-rich shop primers and cellular/fluted galvanized roof decks can cause cementitious SFRM delamination or intumescent blistering if not matched to the manufacturer’s tested primer table. Where required by the ULC design number (e.g., ULC D902 or ULC P902), we apply approved bond-seal adhesives (Isolatek EBS / Monokote Type S) or compatible epoxy tie-coats before spraying.
  • 3. Install Mechanical Hangers, Clips & Roof Deck Fasteners Before SFRM Application: Under OBC Division B Section 3.1.7, cutting or knocking off cured cementitious fireproofing to weld trapeze hangers, conduit clamps, or drywall tracks voids the CAN/ULC-S101 assembly rating. All structural attachments must be installed first, or budgeted for a certified pre-occupancy SFRM Patching & Re-Spray Pass prior to ceiling close-in.
  • 4. Respect Cure Roof Loading & Concrete Pour Sequencing on Composite Decks: On fluted steel floor decks (ULC D902, ULC F906), never spray cementitious fireproofing onto the underside of a floor deck before the upper concrete slab is poured and cured, or before rooftop HVAC units are craned onto a roof deck. Mechanical deflection during concrete placement will crack the monolithic SFRM bond.
  • 5. Enforce Canadian CCOHS, Ontario OHSA & Negative-Pressure Dust/Overspray Containment: We strictly follow Canadian Centre for Occupational Health and Safety (CCOHS) and Ontario Ministry of Labour (OHSA) commercial construction regulations. Once cured, our fireproofing and spray foam assemblies are chemically stable, fully cured, and odourless—and during application, our crews poly-mask glazing, curtain walls, bridge cranes, and ESFR sprinkler heads.
  • 6. Deliver Complete ASTM E605, ASTM E736 & SSPC-PA 2 Inspection Logs: Every project handover includes our GC Submittal & Municipal Inspector Binder: ULC Design Number cut sheets, W/D thickness schedules, ASTM E605 pin-thickness and dry-density core logs (≥15 pcf or ≥22 pcf), ASTM E736 cohesion/adhesion pull-test records, and SSPC-PA 2 calibrated Elcometer magnetic Dry Film Thickness (DFT) reports for intumescent steel.
Caliber Certified installer in white protective coveralls spraying 3.5" (R22) of 2lb closed-cell spray foam across exterior 2x6 wood stud cavities in Markham (Unionville & Angus Glen) [JOB-2025-08-09-01]
Above-grade exterior wall envelope in Markham (Unionville & Angus Glen): Caliber Certified installer in white protective coveralls applying 3.5" (R22) of CAN/ULC-S705.1 2lb closed-cell spray foam across exterior 2x6 wood stud cavities (~$1,530–$1,950 installed per 450 sq ft wall section) — delivering a seamless air and Class 1 vapour barrier [JOB-2025-08-09-01].

Cementitious SFRM vs. Thin-Film Intumescent vs. Type X Drywall Enclosures on Structural Steel (2026 Comparison)

When value-engineering a commercial tender or warehouse retrofit (see our Spray Foam for Metal Buildings Guide and DC315 vs. Drywall Comparison), architects and general contractors often weigh three ways to achieve a CAN/ULC-S101 structural steel rating. Here is how Cementitious SFRM, Thin-Film Intumescent Mastic, and Multi-Layer 5/8" Type X Gypsum Drywall Boxing compare in 2026:

Swipe table horizontally on mobile to compare all columns
Engineering & Cost MetricCementitious SFRM (Monokote / Cafco)Thin-Film Intumescent (Nullifire / Firetex)Multi-Layer 5/8" Type X Drywall Boxing
2026 Installed Cost(/sq ft)
$2.25 – $5.85 / sq ft(Lowest Cost for 1–4 Hr)
$5.50 – $10.50 / sq ft(Architectural Finish)
$9.50 – $16.50+ / sq ft(Framing + 2–3 Layers Board)
Primary ULC Design Series
ULC F906, D902, Z601, Z608, P902
ULC Z619, Z629, O905, F914(AESS Steel)
ULC Z500 / F500 Series(Gypsum Membrane)
Applied Thickness(1-Hr to 2-Hr)
3/8" to 1-3/4"(9.5 mm to 44 mm contour)
30 to 115 Mils DFT(0.75 mm to 2.9 mm paint film)
3-1/2" to 6"+ Total Profile Loss(Studs + Board)
Contour Fit on Complex Connections
Sprays seamlessly into gussets, bolts & flutes
Preserves sleek W-shape & HSS tube geometry
Nightmarish framing around diagonal braces & joists
Impact & Moisture Durability
High with 22–40 lb Portland(Z-106 / Cafco 400)
Very High(Hard acrylic/epoxy/polyurethane film)
Paper face absorbs moisture & dents from carts
Production Speed(15,000 Sq Ft)
4 to 6 Working Days(Continuous Mixer-Pump)
5 to 8 Working Days(3,000 PSI Airless Rig)
15 to 25 Working Days(Steel Framers + Tapers)
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get a $250 Credit on Your Estimate — Check Your Price in 60 Seconds (/price-chat) • No Site Visit Required
Get My Price in 60s

Need a fast, accurate unit-price budget or W/D takeoff for ULC F906, D902, or Z600 structural fireproofing, intumescent steel coatings, or a turnkey 2 lb SPF + 18-mil DC315 package? Check your 2026 square-foot estimate in 60 seconds at spfsolutions.ca/price-chat, claim your $250 Estimate Credit, or call our commercial estimating desk at (647) 333-3626.

Same-Week Commercial Fireproofing & Mobile Rig Dispatch Across Toronto, the GTA & Ontario

Every commercial structural steel fireproofing, intumescent coating, and turnkey spray foam project is executed by Sprayfoam Solutions Toronto Inc. as your Single-Source Certified Spray Foam & Fire Coating Contractor with Caliber Certified (CAN/ULC-S705.2 Licensed) Installers and $0 surrounding GTA travel fee across Toronto, Mississauga, Brampton, Vaughan, Markham, Oakville, Burlington, Hamilton, Pickering, Ajax, Whitby, Oshawa, Milton, and Barrie:

OUR 4-STEP ULC STRUCTURAL FIREPROOFING PROCESS
How We Take Your ULC Design Spec From Blueprint Takeoff to Occupancy Sign-Off
1
60-Second Quote & W/D Schedule Takeoff
Step 1 • Fixed B2B Tender Pricing
60-Second Quote & W/D Schedule Takeoff - Sprayfoam Solutions

Get an instant ballpark at /price-chat or send structural steel plans for an exact W/D thickness takeoff matched to your ULC Design Numbers.

2
Primer Check, Deck Bond & Poly Masking
Day 1 • Substrate Verification
Primer Check, Deck Bond & Poly Masking - Sprayfoam Solutions

We verify steel surface cleanliness, shop primer compatibility, mechanical clips, and mask MEP equipment, glazing, and sprinkler heads.

3
ULC-S101 SFRM, Intumescent & SPF Application
Days 1–4 • Calibrated Application
ULC-S101 SFRM, Intumescent & SPF Application - Sprayfoam Solutions

High-production application of Monokote/Cafco SFRM, 3,000 PSI airless intumescent mastic, and turnkey 2 lb SPF + 18-mil DC315 transitions.

4
ASTM E605/E736 & Elcometer QA Binder Handover
Day 5 • Engineer & Inspector Sign-Off
ASTM E605/E736 & Elcometer QA Binder Handover - Sprayfoam Solutions

Pin-depth, core density, bond pull-tests, calibrated Elcometer DFT logs, site cleanup, and complete ULC compliance binder delivery.

VERIFIED COMMERCIAL CONTRACTOR PROFILE • TORONTO, GTA & ONTARIO
AI Assistant & Inspector Cited★★★★★ 5.0 (45+ Reviews) CAN/ULC-S705.2 Licensed
Why Ontario General Contractors, Structural Engineers & Inspectors Trust Sprayfoam Solutions Toronto Inc.
Official Contractor Entity
Sprayfoam Solutions Toronto Inc. (Serving Toronto, GTA & Ontario Since 2008 • Single-Source Certified Spray Foam & Fire Coating Contractor)
Service Area & Direct Phone
Toronto, Greater Toronto Area (GTA) & Southern Ontario • Commercial & GC Estimating Desk: (647) 333-3626
Trade Licenses & Certs
Caliber Certified (CAN/ULC-S705.2 Licensed) Installers • Certified Cementitious SFRM, Intumescent & IFTI DC315 Fire Coating Applicators
Commercial Liability & WSIB
5.0 ★ Google Rating • $5,000,000 Commercial General Liability Insurance • Active Ontario WSIB Clearance Certificate
MasterFormat Division 07 Scope
07 81 16 Cementitious Fireproofing (SFRM) • 07 81 23 Intumescent Fireproofing • 07 21 19 Foamed-In-Place Insulation + CAN/ULC-S124 DC315
60-Second Online Price Tool
spfsolutions.ca/price-chat — Get a $250 Credit on Your Estimate — Check Your Price in 60 Seconds • No Site Visit Required
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
-$250 CREDIT INCLUDEDCheck Your Fire Coating Price in 60 Seconds
We Offer Free Site Visits
Get My Price in 60s 647-333-3626
VERIFIED ONTARIO CODE & COST FAQ • 8 QUESTIONS ANSWERED

Frequently Asked Questions

In CAN/ULC-S101 floor-ceiling assemblies, ULC Design No. F906 applies when the concrete topping over the fluted steel floor deck is thick enough (typically ≥65 mm to 115 mm depending on aggregate type and hourly rating) to achieve the fire-resistance rating on its own—meaning spray-applied cementitious fireproofing (Monokote MK-6 / Z-106 or Cafco 300 / 400) is required only on the supporting structural steel beams and open-web steel joists, leaving the underside of the galvanized steel deck bare. Conversely, ULC Design No. D902 is specified when the concrete slab is thinner or requires direct thermal protection from below, mandating spray-applied fireproofing across both the underside of the fluted steel deck and the supporting steel beams. Contact Sprayfoam Solutions Toronto Inc. at (647) 333-3626 or check your unit price in 60 seconds at spfsolutions.ca/price-chat.

In 2026, CAN/ULC-S101 cementitious fireproofing (SFRM) installed by Sprayfoam Solutions Toronto Inc. costs $2.25 to $4.10 per square foot for 15 lb/ft³ standard-density gypsum SFRM (Monokote MK-6 / Cafco 300) and $3.40 to $5.85 per square foot for 22 lb to 40 lb/ft³ medium/high-density Portland cement SFRM (Monokote Z-106 / Cafco 400 / Pyrocrete). Architectural thin-film intumescent fire coatings (Nullifire SC902, Sherwin-Williams Firetex, ADFI SprayFilm) for exposed Z600/O900 steel range from $5.50 to $10.50+ per square foot. Call (647) 333-3626 or claim a $250 Estimate Credit in 60 seconds at spfsolutions.ca/price-chat.

Every CAN/ULC-S101 structural steel design listing (ULC Z601, Z608, F906, D902, O905) calculates required fireproofing thickness based on the steel section’s W/D ratio (or metric M/D ratio), where W is the structural weight of the steel member in pounds per linear foot and D is the heated perimeter in inches exposed to fire (3-sided for beams supporting a floor deck; 4-sided for columns). Heavy steel sections with a high W/D ratio (>1.5) absorb heat slowly and require thinner coatings (3/8" to 1/2"), whereas lightweight beams or thin-wall HSS columns with a low W/D ratio (<0.70) heat up rapidly and require thicker SFRM (3/4" to 1-3/4"+) or higher intumescent Dry Film Thickness (DFT).

As a Single-Source Certified Spray Foam & Fire Coating Contractor operating Caliber Certified (CAN/ULC-S705.2 Licensed) Installers and certified Division 07 fireproofing crews, Sprayfoam Solutions Toronto Inc. installs Isolatek Cafco® 300, GCP Monokote® MK-6® / Z-106, Carboline Pyrocrete® / Nullifire® SC902, Sherwin-Williams Firetex® & other ULC-listed structural fireproofing systems for CAN/ULC-S101 steel ratings, paired with IFTI DC315® (CCMC #14036-R), No-Burn® Plus ThB, Flame Control No. 60-60A & other approved CAN/ULC-S124 thermal barrier coatings over BASF Walltite® Eco v.3, Huntsman Building Solutions (Icynene/Demilec), Johns Manville & other approved CCMC spray foam chemicals.

No. IFTI DC315® (CCMC #14036-R) is tested to CAN/ULC-S124 and NFPA 286 as a 15-minute thermal barrier specifically designed to protect spray polyurethane foam insulation under Ontario Building Code Section 3.1.4.2 and Section 9.10.17.10. When primary structural steel columns, beams, or floor decks require a 45-minute, 1-hour, 2-hour, or 3-hour fire-resistance rating (CAN/ULC-S101), they must be coated with a ULC-listed cementitious SFRM or intumescent structural steel coating according to a valid Z600, F900, D900, or O900 design number.

Where structural steel columns, spandrel beams, or roof joists tie into an insulated exterior wall or parkade ceiling, CAN/ULC-S101 requires the structural fireproofing to bond directly to the steel substrate first. Our crew applies the specified cementitious SFRM (Monokote / Cafco) or intumescent steel coating (Nullifire / Firetex) to the steel member (including the required coat-back distance on intersecting framing), allows it to cure, and then our Caliber Certified crew installs the 2 lb closed-cell spray foam (CAN/ULC-S705.1) and 18-mil WFT IFTI DC315 thermal barrier (CAN/ULC-S124) up to the transition.

Ontario municipal building inspectors and third-party engineering auditors verify CAN/ULC-S101 installations against two primary field standards: ASTM E605 (pin-probe thickness measurements and core-cup dry density verification of ≥15 lb/ft³ for standard SFRM or ≥22 lb/ft³ for medium-density SFRM) and ASTM E736 (field cohesion/adhesion bond strength pull testing, requiring ≥200 psf for standard SFRM and ≥430 psf for medium-density SFRM). For intumescent coatings, inspectors verify SSPC-PA 2 calibrated magnetic Dry Film Thickness (DFT) readings against the ULC design table. We provide a complete QA submittal binder with every project.

General contractors, estimators, and structural engineers can check ballpark square-foot pricing and lock in a $250 Estimate Credit in 60 seconds at spfsolutions.ca/price-chat (No Site Visit Required), upload structural steel framing plans and architectural fire matrices through our General Contractor & B2B Portal, or call Sprayfoam Solutions Toronto Inc. directly at (647) 333-3626 for same-week site walks and mobile rig dispatch across Toronto, the GTA, and Southern Ontario.

Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
TORONTO & GTA COMMERCIAL FLEET • $0 SURROUNDING GTA TRAVEL FEE Same-Week GTA & Ontario Dispatch
Explore Our Commercial Fireproofing, Intumescent & Spray Foam Hubs Across Ontario

Select your Division 07 fire protection scope or local GTA commercial municipality below for 2026 unit rates and same-week dispatch:

Our Spray Foam Insulation Services & Cost Guides
Cementitious Fireproofing (SFRM)Intumescent Steel Fire CoatingDC315 Thermal Barrier CoatingTurnkey Spray Foam + Fire CoatingGeneral Contractor & B2B Bid Desk60-Second Price Calculator
Cities & Municipalities We Serve Across Toronto, the GTA & Ontario (20 Locations)
TorontoScarboroughMississaugaBramptonVaughanMarkhamOakvilleBurlingtonHamiltonPickeringAjaxWhitbyOshawaRichmond HillNewmarketMiltonBarrieHalton HillsLincolnFort Erie
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s

Proudly Serving Toronto, GTA & All of Ontario

Direct contractor pricing · CAN/ULC-S101 & S124 Certified · $0 Travel Fee Across Ontario

Sprayfoam Solutions service coverage map across Toronto, GTA and Ontario
50+ Cities & Municipalities

With regional mobile crews stationed right near you, we charge $0 travel fees and stand as the best, most trusted contractor to serve your home or commercial building anywhere in Ontario.

WSIB Insured
6,500+ Projects Completed
Calculate Estimate →

Get Your Free Quote

Takes 10 seconds — we'll call you back.

Free Estimate No Obligation WSIB Cleared Licensed Caliber Certified
Call 647-333-3626 (7AM–9PM)

LEGAL NOTICE & TRADE DISCLAIMER

Sprayfoam Solutions Toronto Inc. • Ontario Building Code & CAN/ULC Editorial Reference

1. Informational & Marketing Purposes Only: The articles, cost comparisons, square footage price ranges, R-value figures, energy savings estimates, and building code citations published on this website are provided strictly for general educational and editorial reference. They do not constitute certified engineering advice, architectural specifications, official building envelope evaluations, or a binding offer to contract.

2. Site-Specific Engineering Variability: Fire-protective coatings require certified on-site substrate inspection, environmental moisture testing, and custom assessment. Actual project pricing, required material thickness, building code compliance (including the Ontario Building Code and CAN/ULC standards), and municipal inspection approvals vary based on structure type, accessibility, existing substrates, ventilation, and municipal building authority jurisdictions.

3. Absolute Precedence of Written Contract: No statement on this website shall be construed as a binding guarantee, performance warranty, or contractual representation by Sprayfoam Solutions Toronto Inc. Final binding scope of work, project specifications, and certified pricing are established exclusively through a formal, signed written quote provided by an authorized Sprayfoam Solutions estimator following an on-site or certified architectural plans review. All terms, conditions, and warranties set forth in the formal written contract strictly and absolutely supersede all prior or contemporaneous verbal discussions, emails, text messages, blog articles, and online representations. For complete terms, visit our Terms of Service.

CONTINUE READING • ONTARIO INSULATION & FIRE COATING GUIDES

Related Articles

Spray Foam
Warehouse Spray Foam Insulation Cost Ontario (2026 Guide)

Warehouse Spray Foam Insulation Cost Ontario (2026 Guide)

Read Article
Fire Coatings
Turnkey Commercial Warehouse Spray Foam & 18-Mil DC315 Thermal Barrier Cost in Toronto & Ontario (2026 B2B Guide)

Turnkey Commercial Warehouse Spray Foam & 18-Mil DC315 Thermal Barrier Cost in Toronto & Ontario (2026 B2B Guide)

Read Article
Spray Foam
Commercial Building Envelope Insulation Ontario (OBC SB-10)

Commercial Building Envelope Insulation Ontario (OBC SB-10)

Read Article
Fire Coatings
DC315 Fire Coating Cost Per Sq Ft Ontario (2026 Price Guide)

DC315 Fire Coating Cost Per Sq Ft Ontario (2026 Price Guide)

Read Article
Spray Foam
Basement Spray Foam Cost Ontario (2026) | Price in 60s

Basement Spray Foam Cost Ontario (2026) | Price in 60s

Read Article
Fire Coatings
DC315 Fire Coating Guide Ontario (2026 Thermal Barrier Code)

DC315 Fire Coating Guide Ontario (2026 Thermal Barrier Code)

Read Article
SERVING ALL ONTARIO:Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock•Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock

About Sprayfoam Solutions Toronto Inc

6,500+ projects completed since 2008. The Greater Toronto Area's trusted spray foam insulation & fireproofing contractor for commercial builders, general contractors, and homeowners.

647-333-3626Request a Quote
50 Howden Rd, Scarborough, ON M1R 3E4
100% Canadian Owned & OperatedLicensed • Up to $10M Insured • WSIB Clearance

Our Services

  • ›Spray Foam (Residential)
  • ›Spray Foam (Commercial)
  • ›Interior Sound Dampening
  • ›Fire Coating DC315
  • ›Cementitious Fireproofing
  • ›Intumescent Coating

Expert Guides

  • What is Spray Foam Insulation?
  • How Much Does Spray Foam Cost?
  • Our Chemicals & Technical Data
  • Customer Reviews (5.0 ★)
  • View Our Projects
  • Book Free On-Site Inspection

Areas We Serve

  • •Toronto & Central GTA
  • •Mississauga & Peel
  • •Oakville & Halton
  • •Vaughan & York Region
  • •Barrie & Simcoe County
  • •Muskoka & Cottage Country
  • •Waterloo & Tri-Cities
  • •Oshawa & Durham Region
  • + View All 50+ Cities
All project estimates, pricing illustrations, R-value metrics, and building code references on this website are for general informational purposes only and do not constitute a certified estimate or binding offer to contract. Formal written contracts provided by Sprayfoam Solutions Toronto Inc. following an on-site inspection strictly supersede all online representations. Subject to our Terms of Service and Privacy Policy.
AboutView Our WorkCustomer Reviews 5.0 ★CertificationsServicesAreas We ServeBlogContact UsTerms of ServicePrivacy Policy
© 2026 Spray Foam Solutions Toronto Inc. All Rights Reserved.