Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home

Residential

Major Projects
  • Custom New Homes
  • Additions & Renovations
  • Muskoka Cottages & Homes
  • Exterior Walls
  • Interior Ceiling Sound Dampening
Targeted Areas
  • Basements
  • Attics & Roof Decks
  • Crawl Spaces
  • Rim Joist Headers
  • Garages & Floors Over Garage
  • Cathedral Ceilings
  • Cantilevers & Overhangs
  • Under-Slab & Radiant Floors
  • Cold Rooms
  • RVs & Vans
  • Swimming Pools

Commercial

Buildings & Facilities
  • Commercial SPF & Fire Coating
  • Warehouse & Industrial
  • Metal Buildings
  • Barns & Agricultural
  • Multi-Unit Buildings
  • Flat Roof Systems
Specialty
  • Shipping Containers
  • Silos & Water Tanks

Code & Expert Guides

  • What is Spray Foam?
  • Cost of Spray Foam
  • Our Sprayfoam Chemicals
  • Certifications & Standards
  • Spray Foam Knowledge Base
Ontario Code & ULC Guides
  • Ontario R-Value & Code Guide
  • CAN/ULC-S705.2 Code Rules
  • Open-Cell vs. Closed-Cell

Thermal Barriers (Foam)

Core Systems
  • DC315 Intumescent Coating
  • Sprayfoam & Fire Coating (2-in-1)
Where Code Requires It
  • Mechanical & Furnace Rooms
  • Exposed Basements & Crawls
  • Attached Garage Ceilings
  • Warehouse Exposed Foam Decks
  • Unvented Attics & Roof Decks
  • Rim Joists & Floor Headers

Structural Fireproofing

Fireproofing Systems
  • Cementitious Fireproofing (SFRM)
  • Intumescent Fire Coating (Thin-Film)
Structural Assemblies
  • Structural Beams & Columns
  • Metal Floor & Roof Decks
  • Commercial Parkades & Garages
  • Architectural Exposed Steel (AESS)
  • Request Fire Spec & Quote

Code & Expert Guides

  • What is DC315 Fire Coating?
  • Cost of DC315 Fire Coating
  • Our Fire Coating Chemicals
  • Certifications & Standards
  • Fire Coating Knowledge Base
Ontario Code & ULC Guides
  • Ontario 15-Min Thermal Barrier
  • ULC 1–4 Hr Steel Ratings
  • DC315 vs. Type X Drywall
Locations
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviews
Contact UsGet My Pricing
Serving GTA & Beyond
Sprayfoam SolutionsWe Serve GTA & Across Ontario!
Home
Spray Foam Services
Overview & Guides
What is Spray Foam?Cost of Spray FoamOpen-Cell vs. Closed-CellOntario R-Value & Code Guide
Project Applications
Custom New HomesAdditions & RenovationsMuskoka Cottages & HomesExterior WallsInterior Ceiling Sound DampeningBasementsAttics & Roof DecksCrawl SpacesRim Joist HeadersGarages & Floors Over GarageCathedral CeilingsCantilevers & OverhangsUnder-Slab & Radiant FloorsCold RoomsRVs & VansSwimming Pools
Overview & Guides
Commercial SPF & Fire Coating OverviewCAN/ULC-S705.2 Code RulesCost of Spray Foam
Project Applications
Warehouse & IndustrialMetal BuildingsBarns & AgriculturalMulti-Unit BuildingsFlat Roof SystemsShipping ContainersSilos & Water Tanks
Overview & Guides
Our Sprayfoam ChemicalsCertifications & StandardsSpray Foam Knowledge Base
Fire Coatings
Overview & Guides
DC315 Fire Coating OverviewSprayfoam & DC315 Package (2-in-1)What is DC315 Fire Coating?Cost of DC315 Fire CoatingDC315 vs. Type X DrywallOntario 15-Min Thermal Barrier
Project Applications
Mechanical & Furnace RoomsExposed Basements & CrawlsAttached Garage CeilingsWarehouse Exposed Foam DecksUnvented Attics & Roof DecksRim Joists & Floor Headers
Overview & Guides
Intumescent Fire Coating OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Structural Beams & ColumnsArchitectural Exposed Steel (AESS)Request Fire Spec & Quote
Overview & Guides
Cementitious Fireproofing OverviewULC 1–4 Hr Steel Fire Ratings
Project Applications
Metal Floor & Roof DecksCommercial Parkades & GaragesRequest Fire Spec & Quote
Overview & Guides
Our Fire Coating ChemicalsCertifications & StandardsFire Coating Knowledge Base
Ontario Service RegionsView All 50+ Cities →
Toronto & Central
Toronto · Etobicoke · North York · Scarborough
Peel Region
Mississauga · Brampton · Caledon
York Region
Vaughan · Markham · Richmond Hill · Newmarket
Halton Region
Oakville · Burlington · Milton · Halton Hills
Durham Region
Pickering · Whitby · Oshawa · Ajax · Clarington
Hamilton & Niagara
Hamilton · St. Catharines · Niagara Falls · Brantford
Kitchener / Waterloo / Guelph
Kitchener · Waterloo · Cambridge · Guelph
Barrie & Simcoe County
Barrie · Orillia · Innisfil · Collingwood
Muskoka & Cottage Country
Muskoka · Huntsville · Gravenhurst · Bracebridge
Windsor & Southwestern ON
Windsor · London · Sarnia · Chatham-Kent
Our WorkReviewsContact Us
More Info & Resources
› About Us› Certifications› All Services› Blog & Guides
We Serve GTA & Across Ontario!
Get My Pricing 647-333-3626
Back to Blog·Fire Coatings
11 min read·Updated Nov 15, 2026

Medium & High-Density Cementitious Fireproofing in Ontario (2026): Monokote® Z-106, Z-146 & Cafco® 400 Parkade & Industrial Guide

2026 ONTARIO QUICK COST & CODE SUMMARY SB-12 & CAN/ULC Verified

In Toronto and Ontario, installing 22 lb medium-density (Monokote® Z-106, Cafco® 400) and 40 lb high-density (Monokote® Z-146, Cafco® Fendolite MII) Portland-cement Spray-Applied Fire-Resistive Materials (SFRM) costs $4.50 to $9.20 per sq ft for 1-to-2-hour medium-density parkade and mechanical room assemblies, and $8.80 to $14.80+ per sq ft for 2-to-4-hour high-density industrial and petrochemical assemblies. Installed by Sprayfoam Solutions Toronto Inc. ((647) 333-3626 • spfsolutions.ca/price-chat), high-bond Portland-cement SFRM satisfies CAN/ULC-S101, ASTM E605, and ASTM E736 (>430 to 1,000+ psf bond strength).

Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
Sprayfoam Solutions Toronto Inc. — Commercial Division 07 Cementitious Fireproofing & Thermal Envelope Team· Caliber Certified (CAN/ULC-S705.2)
Medium & High-Density Cementitious Fireproofing in Ontario (2026): Monokote® Z-106, Z-146 & Cafco® 400 Parkade & Industrial Guide
ONTARIO BUILDING CODE & ENGINEERING BRIEF
2026 OBC SB-12 & CAN/ULC-S705.1 Reference
  • Standard 15 lb gypsum-based fireproofing (Monokote MK-6 / Cafco 300) cannot withstand high humidity, freeze-thaw cycling, air-erosion velocity, or mechanical abrasion in unconditioned underground parkades, loading docks, elevator shafts, and industrial plants.
  • Under 2026 Ontario Building Code Part 3 and MasterFormat Section 07 81 16, architects specify 22 lb/ft³ medium-density Portland-cement SFRM (GCP Monokote® Z-106/HY, Isolatek® Cafco® 400 & other ULC-listed structural fireproofing systems) with ≥430 psf bond strength (ASTM E736), or 40–50 lb/ft³ high-density SFRM (Monokote® Z-146, Z-156, Fendolite® MII) with ≥1,000 psf bond strength.

Installed by Sprayfoam Solutions Toronto Inc. ((647) 333-3626 • spfsolutions.ca/price-chat), our turnkey Division 07 crews also pair thermal 2 lb closed-cell spray foam (CAN/ULC-S705.1) with certified thermal barrier assemblies across Ontario.

GUIDE NAVIGATION • 7 SECTIONS Click Any Topic to Jump
In This 2026 Ontario Guide (Quick Jump Links)
  1. 01Medium & High-Density Cementitious Fireproofing in Ontario (2026): 2026 Ontario Overview & Code Essentials
  2. 022026 22 lb & 40 lb Portland-Cement SFRM Cost Per Square Foot Table (Ontario Commercial & Industrial)
  3. 03ASTM E605 Density, ASTM E736 Bond (>430–1,000 psf) & CAN/ULC-S101 Compliance Standards
  4. 046 Critical On-Site Trade Rules for Medium & High-Density Cementitious Fireproofing in Ontario
  5. 0515 lb Standard SFRM vs. 22 lb Medium-Density vs. 40 lb High-Density vs. Intumescent Paint (2026 Comparison)
  6. 06Rapid Division 07 Commercial Mobilization Across Toronto, the GTA & Ontario ($0 GTA Travel Fee)
  7. 07Frequently Asked Questions: Medium & High-Density Cementitious Fireproofing in Ontario
PROJECT HIGHLIGHT • TORONTO, ON
Structural Steel Intumescent & SFRM Fireproofing
1-Hr to 2-Hr • CAN/ULC-S101
Thin-Film Intumescent & Cementitious SFRM (MasterFormat 07 81 00)
  • 12,000 sq ft W-Beams, HSS Columns & Fluted Decking
  • CAN/ULC-S101 Listed Designs (F900 / D900 / Z600)
  • Full DFT / ASTM E605 QA Verification Package
VERIFIED GOOGLE REVIEW • 5.0 ★★★★★ (56+)
NK
Nikola
Verified Google Customer • Sprayfoam Solutions Toronto

“Professional service from start to finish. Fair pricing, great communication, and the installers did a super clean job. Highly recommend Sprayfoam Solutions Toronto.”

  • 5.0 ★ Rating Across 56+ Verified Google Reviews

Medium & High-Density Cementitious Fireproofing in Ontario (2026): 2026 Ontario Overview & Code Essentials

Specifying or bidding medium-density and high-density cementitious fireproofing in Toronto, the GTA, Hamilton, and across Ontario requires strict adherence to MasterFormat Division 07 81 16 and CAN/ULC-S101 structural fire-resistance listings. While standard 15 lb/ft³ low-density gypsum fireproofing (Monokote® MK-6, Cafco® 300) is the economical workhorse for concealed steel beams above dry office drop-ceilings, gypsum-based SFRM absorbs moisture, softens under freeze-thaw cycling, and spalls off when exposed to vehicle exhaust turbulence, forklift bumps, or high-velocity HVAC plenum air.

Whenever structural steel wide-flange beams, fluted Q-decks, or concrete soffits sit inside unheated underground condo and retail parkades, semi-exposed truck loading docks, high-velocity mechanical fan rooms, elevator hoistways, water treatment plants, or heavy industrial facilities, Ontario engineers mandate 22 lb/ft³ medium-density (GCP Monokote® Z-106, Isolatek® Cafco® 400) or 40 lb/ft³ high-density (Monokote® Z-146, Cafco® Fendolite® MII & other ULC-listed structural fireproofing systems) hydraulic Portland-cement fireproofing. Installed by Sprayfoam Solutions Toronto Inc. ((647) 333-3626), our high-output continuous mixer-pump crews and Caliber Certified (CAN/ULC-S705.2 Licensed) thermal insulation teams deliver single-source Division 07 fireproofing and turnkey spray foam + fire coating packages. Check your commercial unit rates in 60 seconds at spfsolutions.ca/price-chat and claim a $250 Credit on Your Estimate with No Site Visit Required.

2026 Ontario Medium & High-Density Cementitious Fireproofing Cost by Density Tier

Compare our 3 commercial and industrial Portland-cement SFRM specification tiers before running your 60-second square-foot takeoff:

22 lb Medium-Density • 1-Hr to 2-Hr
Underground Parkades & Mechanical Rooms
$4.50 – $7.40 / sq ft
Monokote® Z-106 / HY • Cafco® 400
  • ≥22 lb/ft³ Portland-Cement SFRM
  • ≥430 psf Bond Strength (ASTM E736)
  • High-Humidity & Freeze-Thaw Resistant
  • Includes $250 Estimate Credit
Get My Price in 60s
Most Specified • 2-Hr to 3-Hr Heavy Duty
Loading Docks, Hoistways & Transit Hubs
$6.80 – $10.50 / sq ft
Monokote® Z-106 + Metal Lath / 22–28 lb Spec
  • CAN/ULC-S101 D900/F900/Z600 Series
  • Abrasion & Air-Erosion Resistant
  • Full ASTM E605/E736 Field QA Binder
  • Multi-Pump Dispatch
Get My Price in 60s
40–50 lb High-Density • Industrial / UL 1709
Industrial Plants, Tunnels & Petrochemical
$8.80 – $14.80+ / sq ft
Monokote® Z-146 / Z-156 • Fendolite® MII
  • ≥40 lb/ft³ Hard-Coat Portland Cement
  • ≥1,000–2,000 psf Bond Strength
  • Weather-Exposed & Hydrocarbon Fire Rated
  • Includes $250 Credit
Get My Price in 60s

2026 22 lb & 40 lb Portland-Cement SFRM Cost Per Square Foot Table (Ontario Commercial & Industrial)

Unlike thin-film intumescent fire coating for exposed architectural steel, cementitious fireproofing is priced by density class (15 lb, 22 lb, or 40 lb/ft³), ULC design thickness (0.50" to 2.25"+ depending on steel W/D ratio and hourly rating), and surface preparation requirements (such as galvanized deck primers or mechanical rib lath). Here is our transparent 2026 Ontario unit-price matrix across project volumes from 2,500 sq ft to 100,000+ sq ft:

Swipe table horizontally on mobile to compare all columns
SFRM Material Class & Brand SpecTarget Density & Bond (ASTM E605 / E736)Typical ULC Hourly Rating & Thickness2026 Installed Rate (/sq ft)Typical Commercial / Industrial Application
15 lb Standard Gypsum SFRM(Monokote MK-6 / Cafco 300 Baseline)
≥15 lb/ft³ • ≥200 psf bond
1-Hr to 2-Hr(0.50" – 1.25")
$2.65 – $4.75 / sq ft
Dry conditioned interior steel above drop ceilings
22 lb Medium-Density Portland SFRM(Monokote Z-106 / Cafco 400 — 1-Hr)
≥22 lb/ft³ • ≥430 psf bond
1-Hr CAN/ULC-S101(0.50" – 0.85")
$4.50 – $6.40 / sq ft
Underground parkade beams, ramps & unheated soffits
22 lb Medium-Density Portland SFRM(Monokote Z-106 / Cafco 400 — 2-Hr)
≥22 lb/ft³ • ≥430 psf bond
2-Hr CAN/ULC-S101(0.95" – 1.65")
$6.10 – $8.90 / sq ft
Condo parkade transfer slabs, mechanical rooms & elevator shafts
22 lb Medium-Density + 3-Hr Assembly(Structural Columns & Primary Girders)
≥22 lb/ft³ • ≥430 psf bond
3-Hr CAN/ULC-S101(1.50" – 2.25")
$7.80 – $10.50 / sq ft
High-rise podium steel, hospital & institutional cores
40 lb High-Density Portland SFRM(Monokote Z-146 / Cafco Fendolite MII)
≥40 lb/ft³ • ≥1,000+ psf bond
1-Hr to 4-Hr(0.65" – 2.00")
$8.80 – $14.80+ / sq ft
Loading bays, transit tunnels, manufacturing & UL 1709 plants
Turnkey Parkade Soffit Package(2 lb Closed-Cell SPF + 18-Mil DC315)
CAN/ULC-S705.1 + S124
R-21 to R-31 + 15-Min Thermal Barrier
$5.10 – $7.60 / sq ft
Heated condo/retail floors above unheated underground parking
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s

Underground Parkades, Mechanical Rooms & Loading Docks (Why 22 lb Monokote Z-106 & Cafco 400 Are Mandatory)

In Toronto and GTA mid-rise and high-rise construction, the structural transfer beams, steel columns, and metal composite decks inside underground parking garages (P1 to P5 levels) and open-bay shipping/receiving docks experience 85%+ relative humidity in summer and sub-zero road-salt mist in winter. Standard 15 lb gypsum SFRM is water-soluble and rapidly delaminates in these zones. Specifying 22 lb medium-density Portland-cement SFRM (GCP Monokote® Z-106 / Z-106 HY, Isolatek® Cafco® 400 & other ULC-listed structural fireproofing systems) solves four critical building-envelope challenges:

  • 1. Hydraulic Portland-Cement Binder Resists Humidity & Condensation: Because Monokote® Z-106 and Cafco® 400 cure via hydraulic Portland-cement hydration rather than soft gypsum crystallization, they withstand persistent dampness, wash-down splash, and seasonal freeze-thaw cycles inside unconditioned parkades and open parking structures.
  • 2. More Than Double the Cohesive & Adhesive Bond Strength (≥430 psf per ASTM E736): At 430+ lbs per square foot bond strength, 22 lb medium-density SFRM resists structural vibration from overhead truck loading docks, subway proximity, and heavy air-handling units without flaking.
  • 3. High-Velocity HVAC Plenum & Elevator Shaft Air-Erosion Resistance (ASTM E859): Mechanical penthouses, return-air plenums, and high-speed elevator hoistways generate intense air pressure differentials. Medium-density 22 lb cementitious fireproofing passes ASTM E859 air-erosion testing at 0.00 g/ft² without shedding dust into hospital or commercial HVAC ductwork.
  • 4. Seamless Coordination With Turnkey Parkade Thermal Insulation (2 lb SPF + DC315): Where an unheated P1 underground parkade ceiling sits directly beneath ground-floor retail units or residential condo suites, structural steel requires CAN/ULC-S101 cementitious fireproofing while the concrete soffit requires OBC SB-10 thermal insulation (R-24 to R-31). As a single-source Division 07 contractor, Sprayfoam Solutions Toronto Inc. installs both your 22 lb cementitious steel fireproofing AND your turnkey 2 lb closed-cell spray foam + 18-mil DC315 thermal barrier (IFTI DC315, No-Burn Plus ThB, Flame Control 60-60A & other approved CAN/ULC-S124 / CCMC intumescent thermal barrier coatings) under one contract.
5" (R31) of 2lb closed-cell spray foam on flat ceiling joists in Toronto (Forest Hill & Rosedale) [JOB-2021-10-08-01]
Zero-draft joist cavity insulation in Toronto (Forest Hill & Rosedale): 5" (R31) of 2lb closed-cell spray foam applied between horizontal ceiling joists (~$2,650–$4,400 typical zone cost) for Medium & High-Density Cementitious Fireproofing in Ontario [JOB-2021-10-08-01].

High-Impact Industrial, Infrastructure & Petrochemical Zones (40 lb Monokote Z-146 & Cafco Fendolite MII)

When structural steel is located in high-abuse industrial bays, forklift traffic corridors (<10 ft above finished floor), wastewater treatment plants, transit tunnels, power generation stations, or petrochemical/refinery units, architects step up to 40 lb to 50 lb/ft³ high-density Portland-cement SFRM (GCP Monokote® Z-146 / Z-156, Isolatek® Cafco® Fendolite® MII & other ULC-listed structural fireproofing systems). Delivering ≥1,000 to 2,000+ psf bond strength (ASTM E736) and >500 psi compressive strength (ASTM E761), 40 lb high-density fireproofing forms a rock-hard concrete-like protective jacket rated for both CAN/ULC-S101 cellulosic fires and UL 1709 rapid-rise hydrocarbon pool fires (2,000°F in 5 minutes).

ASTM E605 Density, ASTM E736 Bond (>430–1,000 psf) & CAN/ULC-S101 Compliance Standards

Under the 2026 Ontario Building Code Division B Part 3 (Section 3.1.7 & SB-2) and National Research Council Canada / ULC Standards, every medium- and high-density cementitious fireproofing installation in Ontario must be applied in strict accordance with its tested ULC Design Number (D900, F900, Z600, O900, or U900 series) and verified by independent third-party field testing (see our Commercial Fireproofing Requirements in Toronto Guide).

DIVISION 07 81 16 • ARCHITECT, ENGINEER & GC SUBMITTAL SPEC SHEET 2026 Ontario Building Code Verified
2026 Ontario Medium & High-Density Cementitious Fireproofing Technical Spec Sheet
01MasterFormat & Building Code
CSI MasterFormat 07 81 16 (Spray-Applied Fire-Resistive Materials) • 2026 Ontario Building Code Part 3 (Section 3.1.7)
02Fire-Resistance Test Standards
CAN/ULC-S101 / ASTM E119 (1-Hr, 1.5-Hr, 2-Hr, 3-Hr & 4-Hr Structural Ratings) + UL 1709 (Rapid-Rise Hydrocarbon Fire)
03Approved Medium & High-Density Systems
GCP Monokote® Z-106 / Z-106 HY (22 lb), Monokote® Z-146 / Z-156 (40 lb), Isolatek® Cafco® 400 (22 lb), Fendolite® MII & other ULC-listed structural fireproofing systems
04Physical Performance Benchmarks
ASTM E605 Density (≥22 lb/ft³ Medium / ≥40 lb/ft³ High) • ASTM E736 Bond (≥430 psf Medium / ≥1,000 psf High) • CAN/ULC-S102 FSR 0 / SDC 0
05Turnkey SPF + Thermal Barrier Option
CAN/ULC-S705.1 2 lb Closed-Cell Spray Foam (Caliber Certified CAN/ULC-S705.2) + 18-Mil IFTI DC315 (CAN/ULC-S124 / CCMC 14036-R)
06Third-Party QA & Submittal Package
Full ULC Design Submittals, Primer Compatibility Logs, Daily Wet-Depth Pin Logs & Third-Party ASTM E605/E736 Core Test Support
3.5" (R22) of 2lb closed-cell spray foam around poly-masked window framing in Mississauga (Lorne Park & Port Credit) [JOB-2023-07-22-01]
Monolithic thermal & air-barrier seal in Mississauga (Lorne Park & Port Credit): 3.5" (R22) of 2lb closed-cell spray foam applied inside exterior wall stud cavities around poly-masked window framing (<0.02 L/s·m² @ 75 Pa airtightness) for Medium & High-Density Cementitious Fireproofing in Ontario [JOB-2023-07-22-01].
TECHNICAL SPECS • INTERACTIVE SFRM DENSITY SELECTOR
Which Cementitious Fireproofing Density Does Your Ontario Project Require?
SYSTEM / COATING TYPE
22 lb Portland SFRM(Monokote® Z-106 / Cafco® 400)

Moisture, abrasion & freeze-thaw resistant Portland cement.

REQUIRED THICKNESS
0.50" – 1.85" ULC(By W/D Ratio & 1–3 Hr Rating)

Applied directly to structural beams, columns & fluted decks.

CODE & FIRE PERFORMANCE
≥430 psf Bond(ASTM E736 / CAN/ULC-S101)

Ideal for parkades, mechanical rooms & elevator shafts.

APPLICATION RATIONALE

Whenever structural steel is located in unheated underground parking garages, mechanical fan rooms, elevator shafts, or covered loading docks, 22 lb/ft³ medium-density Portland-cement SFRM (Monokote Z-106 or Cafco 400) prevents moisture softening and delivers ≥430 psf bond strength—passing third-party ASTM E605 and E736 testing on the first inspection.

CONCRETE FOUNDATION WALL1/2" DRYWALL (THERMAL BARRIER)22 LB PORTLAND SFRM (Z-106)≥430 PSF BOND • PARKADE RATEDFREEZING DAMP SOILWARM & COZY BASEMENT
SYSTEM / COATING TYPE
40 lb Hard-Coat SFRM(Monokote® Z-146 / Fendolite® MII)

High-impact industrial & exterior-exposure Portland cement.

REQUIRED THICKNESS
0.65" – 2.25" ULC(1–4 Hr Cellulosic & UL 1709)

Spray or trowel finish over galvanized lath or primed steel.

CODE & FIRE PERFORMANCE
≥1,000 psf Bond(>500 PSI Compressive Strength)

Resists forklift impact, weather & hydrocarbon fires.

APPLICATION RATIONALE

In heavy industrial manufacturing plants, lower-level columns subject to mechanical impact, transit infrastructure, and petrochemical facilities, 40 lb/ft³ high-density Portland-cement SFRM provides ≥1,000 psf bond strength and >500 psi compressive strength—delivering permanent 1-to-4-hour CAN/ULC-S101 and UL 1709 protection.

CONCRETE FOUNDATIONWOOD SILL PLATERIM JOISTMAIN FLOOR SUBFLOORFLOOR JOIST CAVITY (SIDE VIEW)40 LB HIGH-DENSITY (Z-146)≥1,000 PSF BOND • INDUSTRIALOUTSIDE COLD AIR & MOISTUREWARM & DRAFT-FREE BASEMENT
SYSTEM / COATING TYPE
2 lb SPF + DC315 / SFRM(Single-Source Division 07)

Thermal insulation + code fire protection under one contract.

REQUIRED THICKNESS
3.5"–5" SPF + Fire Coat(R-21–R-31 + OBC 3.1.4.2 / S101)

Eliminates split-trade scheduling delays on parkade slabs.

CODE & FIRE PERFORMANCE
OBC SB-10 + S124/S101(Thermal + Fire Sign-Off)

One mobilization for structural steel + heated slab soffits.

APPLICATION RATIONALE

Underground parkade ceilings below heated retail or residential floors require both structural fireproofing on steel girders (CAN/ULC-S101) and R-24 to R-31 thermal insulation on concrete soffits (OBC SB-10). Sprayfoam Solutions Toronto Inc. installs both 22 lb cementitious SFRM and 2 lb closed-cell spray foam + 18-mil DC315 thermal barrier with zero trade handoff gaps.

MAIN FLOOR SUBFLOOR (PLYWOOD / OSB)RESILIENT CHANNEL + 5/8" TYPE X DRYWALL CEILINGTURNKEY PARKADE DIVISION 07MAIN FLOOR LIVING SPACE (FOOTSTEPS & VOICES)QUIET BASEMENT APARTMENT / SUITE (SFRM STEEL + SPF/DC315 SOFFIT)

THE SPRAY FOAM EXPERTS

That Actually Lower Your Energy Bills
★★★★★5.0 Google Rating•55+ Verified Reviews•Serving Across Ontario
STEP 1: 60-SECOND PRICE CHECK
LOCK IN DIRECT CONTRACTOR PRICING

Fast Response & Quotes · No Commitment!

Tap to Select Your Project:
or call directly: 647-333-3626
VERIFIED, CERTIFIED & LISTED ON
Google5.0 ★ Verified
HomeStarsVerified Pro
Houzz ProListed Contractor
TrustedProsCanadian Directory
Caliber CertifiedCAN/ULC-S705.2
WSIB & CCMCOntario Cleared

6 Critical On-Site Trade Rules for Medium & High-Density Cementitious Fireproofing in Ontario

Because 22 lb and 40 lb Portland-cement fireproofing slurries pump at higher pressures and cure into dense hydraulic matrices, general contractors and site superintendents must coordinate six technical field rules before our pump trucks mobilize:

  • 1. Verify Shop-Primer Compatibility & Galvanized Deck Bonding (Spatterkote® / Bond-Seal): Bare structural steel must be free of mill scale, cutting oil, and loose rust. Where structural steel has been shop-primed with alkyd or epoxy primer—or where spraying onto slick galvanized composite floor decking—ULC listings frequently require a manufacturer-approved bonding adhesive (GCP Spatterkote® SK-3 or Isolatek® Type EBS) so the heavy 22 lb/40 lb wet slurry achieves full ≥430–1,000 psf adhesion.
  • 2. Install Mechanical Metal Lath on Deep-Web Girders & High-Density Exterior Steel When Required by ULC Design: Under specific CAN/ULC-S101 designs (especially 40 lb Monokote® Z-146 on large structural shapes or unrestrained beams subject to vibration), galvanized expanded metal lath or 2"×2" wire mesh must be mechanically fastened to the steel flanges prior to spraying.
  • 3. Complete Overhead Mechanical Hangers, Sprinkler Mains & Conduit Drops BEFORE Spraying: Once 22 lb or 40 lb Portland-cement fireproofing cures, it is rock-hard. All concrete drop-in anchors, trapeze hangers, sprinkler branch clamps, and steel Partition top-track clips must be installed before we spray so sub-trades do not chisel off cured fireproofing and trigger a municipal Fire Marshal deficiency hold.
  • 4. Maintain Minimum +4.4°C (40°F) Substrate & Ambient Temperature During 24-Hour Hydraulic Cure: Even though cured Monokote® Z-106 and Cafco® 400 are 100% freeze-thaw durable for the life of the building, fresh wet Portland-cement slurry cannot freeze in the hose or on cold winter steel during application and the first 24 hours of hydration. In winter parkade builds, temporary hoarding and indirect heaters keep steel above +4.4°C.
  • 5. Schedule Independent Third-Party ASTM E605 (Density) & ASTM E736 (Cohesion/Adhesion) Field Testing Early: Ontario municipal building officials and project engineers require third-party testing agencies (such as Pinchin,WSP, Englobe, or EXP) to measure wet/dry pin thickness (ASTM E605) and pull-test bond caps (ASTM E736). Our lead applicator logs wet-depth pin checks every 100 sq ft during application so third-party lab inspectors sign off with zero rework.
  • 6. Never Apply Cementitious SFRM Directly Over Flexible Spray Foam Without Approved Transition Details: Rigid hydraulic cementitious fireproofing and flexible polyurethane spray foam have different thermal expansion coefficients. Where your project includes both structural steel fireproofing and commercial spray foam insulation, we fireproof the structural steel first with Monokote Z-106 / Cafco 400 and protect the adjacent spray foam with certified 18-mil IFTI DC315 thermal barrier coating (CAN/ULC-S124 / CCMC #14036-R).
5" (R31) of 2lb closed-cell spray foam on a sloped cathedral ceiling roof deck and 3.5" (R22) on exterior walls in Brampton (Castlemore & Credit Valley) [JOB-2025-07-17-01]
Unvented roof deck & envelope assembly in Brampton (Castlemore & Credit Valley): 5" (R31) of 2lb closed-cell spray foam to the sloped cathedral ceiling roof deck and 3.5" (R22) in the exterior wall stud cavities (~$5.25–$6.85/sq ft roof-deck rate) to prevent winter condensation and ice damming [JOB-2025-07-17-01].

15 lb Standard SFRM vs. 22 lb Medium-Density vs. 40 lb High-Density vs. Intumescent Paint (2026 Comparison)

General contractors and estimators comparing specifications in our Cementitious vs. Intumescent Fireproofing Guide and Ontario Fireproofing Cost Per Sq Ft Guide can use this side-by-side matrix to select the exact code-approved system:

Swipe table horizontally on mobile to compare all columns
Technical & Cost Metric15 lb Standard SFRM (Monokote MK-6 / Cafco 300)22 lb Medium-Density SFRM (Monokote Z-106 / Cafco 400)40 lb High-Density SFRM (Monokote Z-146 / Fendolite)Thin-Film Intumescent Coating (AESS Exposed Steel)
Primary Binder Chemistry
Gypsum / Vermiculite
100% Hydraulic Portland Cement
High-Strength Portland Cement
Acrylic / Epoxy Intumescent Char
Dry Density(ASTM E605)
≥15 lb/ft³(240 kg/m³)
≥22 lb/ft³(352 kg/m³)
≥40 lb/ft³(640 kg/m³)
Thin Film(18 to 140 mils DFT)
Bond Strength(ASTM E736)
≥200 psf
≥430 psf(>2× stronger)
≥1,000 – 2,000 psf(>5× stronger)
Chemical Cross-Linked Bond
Humidity & Freeze-Thaw
Dry Concealed Interior Only
Yes — Parkades, Docks & Shafts
Yes — Exterior & Heavy Industrial
Interior & Conditioned AESS
Surface Finish Appearance
Textured Acoustical Stipple
Hard Textured Cementitious
Dense Troweled or Spray Cement
Smooth Architectural Paint Finish
2026 Installed Cost(/sq ft)
$2.65 – $4.75 / sq ft
$4.50 – $9.20 / sq ft
$8.80 – $14.80+ / sq ft
$6.50 – $15.50+ / sq ft
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get a 24-Hour Division 07 Cementitious Takeoff or Check Ballpark Pricing in 60 Seconds
Get My Price in 60s

Pricing an underground parkade, commercial podium, mechanical room retrofit, or industrial plant in Toronto or Ontario? Check instant square-foot pricing in 60 seconds at spfsolutions.ca/price-chat or call our commercial estimating desk at (647) 333-3626 to lock in a $250 Credit on Your Estimate with No Site Visit Required and schedule rapid GTA pump-rig mobilization.

Rapid Division 07 Commercial Mobilization Across Toronto, the GTA & Ontario ($0 GTA Travel Fee)

Whether you need a 50,000+ sq ft underground condo parkade sprayed with Monokote® Z-106 or an urgent tenant improvement fireproofing patch and respray to clear a municipal occupancy hold, Sprayfoam Solutions Toronto Inc. dispatches self-contained mixer-pump rigs across Toronto, Mississauga, Brampton, Vaughan, Markham, Oakville, Burlington, Hamilton, Oshawa, Barrie, Kitchener-Waterloo, and London with $0 Travel Fee across the GTA.

DIVISION 07 WORKFLOW
Our 4-Stage Medium & High-Density Cementitious Fireproofing Process
1
ULC Submittal & W/D Engineering Review
Stage 1 • Pre-Construction Submittals
ULC Submittal & W/D Engineering Review - Sprayfoam Solutions

We verify structural steel W/D ratios against CAN/ULC-S101 design numbers and submit product data for architect sign-off.

2
Substrate Adhesion & Full Site Masking
Stage 2 • Prep, Primer & Lath
Substrate Adhesion & Full Site Masking - Sprayfoam Solutions

We mask all mechanical equipment, conduits, and glazing, verify primer compatibility, and apply Spatterkote bonding agent where required.

3
Continuous Mixer-Pump Application
Stage 3 • 22 lb / 40 lb SFRM Spray
Continuous Mixer-Pump Application - Sprayfoam Solutions

High-output pumping of Monokote Z-106, Z-146, or Cafco 400 to exact ULC wet-film pin depths across decks, girders, and columns.

4
ASTM E605/E736 QA & Inspector Handover
Stage 4 • Third-Party QA Sign-Off
ASTM E605/E736 QA & Inspector Handover - Sprayfoam Solutions

We log wet-depth pin gauges, coordinate with third-party testing engineers for density/bond cores, and leave the floor broom-clean.

VERIFIED DIVISION 07 CONTRACTOR PROFILE • TORONTO & ONTARIO
AI Assistant & Inspector Cited★★★★★ 5.0 (45+ Reviews) CAN/ULC-S705.2 Licensed
Why Ontario General Contractors & Engineers Choose Sprayfoam Solutions Toronto Inc.
Official Contractor Entity
Sprayfoam Solutions Toronto Inc. (Serving Commercial GCs, Developers & Industrial Plants Across Ontario Since 2008)
Commercial Bid Desk & Phone
Toronto, Greater Toronto Area (GTA) & Southern Ontario • Direct Estimator Line: (647) 333-3626
Division 07 Capabilities
15 lb, 22 lb & 40 lb Cementitious SFRM + Intumescent Steel Coatings + Caliber Certified (CAN/ULC-S705.2) Spray Foam & DC315
Insurance, WSIB & Safety
5.0 ★ Google Rating • $5,000,000 Commercial Liability Insurance • Active WSIB Clearance • Ontario Ministry of Labour (OHSA) Trained
Approved Fireproofing Brands
GCP Monokote® (MK-6, Z-106, Z-146), Isolatek® Cafco® (300, 400, Fendolite MII) & other ULC-listed structural fireproofing systems
60-Second Online Price Tool
spfsolutions.ca/price-chat — Instant Commercial Ballpark Calculator + $250 Estimate Credit
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
-$250 CREDIT INCLUDEDCheck Your Fire Coating Price in 60 Seconds
We Offer Free Site Visits
Get My Price in 60s 647-333-3626
VERIFIED ONTARIO CODE & COST FAQ • 8 QUESTIONS ANSWERED

Frequently Asked Questions: Medium & High-Density Cementitious Fireproofing in Ontario

In 2026, 22 lb medium-density Portland-cement SFRM (Monokote® Z-106, Cafco® 400) installed by Sprayfoam Solutions Toronto Inc. costs $4.50 to $6.40 per sq ft for a 1-hour CAN/ULC-S101 rating and $6.10 to $9.20 per sq ft for a 2-hour rating in underground parkades, loading docks, and mechanical rooms. Heavy 40 lb high-density SFRM (Monokote® Z-146, Fendolite® MII) costs $8.80 to $14.80+ per sq ft depending on hourly thickness and metal lath requirements. Get your instant ballpark quote at spfsolutions.ca/price-chat or call (647) 333-3626 to lock in a $250 Estimate Credit.

Standard 15 lb/ft³ SFRM (Monokote® MK-6, Cafco® 300) uses a calcined gypsum binder designed strictly for dry, conditioned interior plenums. In unconditioned underground parkades, open loading bays, and damp mechanical shafts, high humidity, road-salt mist, and winter freeze-thaw cycles dissolve gypsum crystals and cause delamination. 22 lb medium-density (Monokote® Z-106, Cafco® 400) uses a hydraulic Portland-cement binder with ≥430 psf bond strength (ASTM E736) that permanently resists moisture and freeze-thaw cycling.

GCP Monokote® Z-106 (and Z-106/HY) is a 22 lb/ft³ medium-density Portland-cement fireproofing (≥430 psf bond strength) specified for high-humidity interior and semi-exposed commercial zones such as underground parking garages, elevator shafts, and mechanical rooms. Monokote® Z-146 is a 40 lb/ft³ high-density Portland-cement fireproofing (≥1,000 psf bond strength) engineered for severe mechanical abrasion zones, weather-exposed exterior steel, industrial processing plants, and UL 1709 hydrocarbon fire exposures.

Both Isolatek® Cafco® 400 and GCP Monokote® Z-106 (along with other ULC-listed structural fireproofing systems) are 22 lb/ft³ medium-density hydraulic Portland-cement SFRMs tested to CAN/ULC-S101, ASTM E605, and ASTM E736 (≥430 psf bond). When a project specification lists one brand as the basis of design under MasterFormat 07 81 16, our engineering desk submits the matching ULC Design Number (D900, F900, or Z600 series) and W/D thickness calculation to the project architect for formal equivalency approval.

Under the Ontario Building Code, independent testing agencies inspect cementitious fireproofing against two primary standards: ASTM E605 (measuring thickness with a calibrated needle gauge across a grid of bays and weighing core samples to verify ≥22 lb/ft³ or ≥40 lb/ft³ dry density) and ASTM E736 (gluing a metal cap to the cured SFRM with polyurethane foam and pulling it with a calibrated spring scale to verify ≥430 psf or ≥1,000 psf cohesive/adhesive bond).

Yes. Sprayfoam Solutions Toronto Inc. ((647) 333-3626 • spfsolutions.ca/price-chat) is a single-source Division 07 contractor. On underground parkades beneath heated retail or residential floors, our Caliber Certified (CAN/ULC-S705.2 Licensed) crews install CAN/ULC-S705.1 2 lb closed-cell spray foam + 18-mil IFTI DC315 thermal barrier on the insulated concrete soffits while our SFRM pump crews apply 22 lb Monokote Z-106 / Cafco 400 to the structural steel girders and columns (see our Structural Steel Fireproofing Guide).

Yes. When electricians, sprinkler fitters, or HVAC contractors scrape off existing fireproofing during a tenant fit-out or mechanical retrofit, municipal building inspectors and Fire Marshals will withhold occupancy until the steel is patched to its rated CAN/ULC-S101 thickness. We dispatch rapid patching crews across Toronto and the GTA to re-spray 15 lb, 22 lb, or 40 lb SFRM and provide your compliance sign-off letter.

Sprayfoam Solutions Toronto Inc. ((647) 333-3626) provides instant square-foot budget ranges + a $250 Estimate Credit in 60 seconds at spfsolutions.ca/price-chat with No Site Visit Required, or you can send structural steel schedules and architectural drawings to our commercial bid desk for a formal 24-hour line-item takeoff.

Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s
ONTARIO COMMERCIAL FIREPROOFING FLEET • $0 SURROUNDING GTA TRAVEL FEE Same-Week GTA & Ontario Dispatch
Explore Our Commercial Fireproofing, Intumescent & Thermal Barrier Hubs

Select your Division 07 fire protection scope or GTA municipality below for local CAN/ULC-S101 and Ontario Building Code specs:

Our Spray Foam Insulation Services & Cost Guides
Cementitious Fireproofing (SFRM)Intumescent Steel Fire CoatingDC315 Thermal Barrier CoatingTurnkey Spray Foam + Fire CoatingCommercial Contractor Partner60-Second Commercial Price Tool
Cities & Municipalities We Serve Across Toronto, the GTA & Ontario (20 Locations)
TorontoMississaugaVaughanBramptonMarkhamOakvilleBurlingtonHamiltonScarboroughPickeringAjaxWhitbyOshawaRichmond HillMiltonNewmarketBarrieMuskokaBellevilleLondon
Claim Your $250 Estimate Credit Today•We Offer Free Site Visits
Get My Price in 60s

Proudly Serving Toronto, GTA & All of Ontario

Direct contractor pricing · CAN/ULC-S101 & S124 Certified · $0 Travel Fee Across Ontario

Sprayfoam Solutions service coverage map across Toronto, GTA and Ontario
50+ Cities & Municipalities

With regional mobile crews stationed right near you, we charge $0 travel fees and stand as the best, most trusted contractor to serve your home or commercial building anywhere in Ontario.

WSIB Insured
6,500+ Projects Completed
Calculate Estimate →

Get Your Free Quote

Takes 10 seconds — we'll call you back.

Free Estimate No Obligation WSIB Cleared Licensed Caliber Certified
Call 647-333-3626 (7AM–9PM)

LEGAL NOTICE & TRADE DISCLAIMER

Sprayfoam Solutions Toronto Inc. • Ontario Building Code & CAN/ULC Editorial Reference

1. Informational & Marketing Purposes Only: The articles, cost comparisons, square footage price ranges, R-value figures, energy savings estimates, and building code citations published on this website are provided strictly for general educational and editorial reference. They do not constitute certified engineering advice, architectural specifications, official building envelope evaluations, or a binding offer to contract.

2. Site-Specific Engineering Variability: Fire-protective coatings require certified on-site substrate inspection, environmental moisture testing, and custom assessment. Actual project pricing, required material thickness, building code compliance (including the Ontario Building Code and CAN/ULC standards), and municipal inspection approvals vary based on structure type, accessibility, existing substrates, ventilation, and municipal building authority jurisdictions.

3. Absolute Precedence of Written Contract: No statement on this website shall be construed as a binding guarantee, performance warranty, or contractual representation by Sprayfoam Solutions Toronto Inc. Final binding scope of work, project specifications, and certified pricing are established exclusively through a formal, signed written quote provided by an authorized Sprayfoam Solutions estimator following an on-site or certified architectural plans review. All terms, conditions, and warranties set forth in the formal written contract strictly and absolutely supersede all prior or contemporaneous verbal discussions, emails, text messages, blog articles, and online representations. For complete terms, visit our Terms of Service.

CONTINUE READING • ONTARIO INSULATION & FIRE COATING GUIDES

Related Articles

Spray Foam
Warehouse Spray Foam Insulation Cost Ontario (2026 Guide)

Warehouse Spray Foam Insulation Cost Ontario (2026 Guide)

Read Article
Fire Coatings
Turnkey Commercial Warehouse Spray Foam & 18-Mil DC315 Thermal Barrier Cost in Toronto & Ontario (2026 B2B Guide)

Turnkey Commercial Warehouse Spray Foam & 18-Mil DC315 Thermal Barrier Cost in Toronto & Ontario (2026 B2B Guide)

Read Article
Spray Foam
Basement Spray Foam Cost Ontario (2026) | Price in 60s

Basement Spray Foam Cost Ontario (2026) | Price in 60s

Read Article
Fire Coatings
Intumescent Fire Coating for Structural Steel Cost in Toronto & Ontario (2026 MasterFormat 07 81 23 Guide)

Intumescent Fire Coating for Structural Steel Cost in Toronto & Ontario (2026 MasterFormat 07 81 23 Guide)

Read Article
Spray Foam
Water Storage Tank, Fire Cistern & Industrial Silo Spray Foam Insulation Cost in Ontario (2026 Contractor Guide)

Water Storage Tank, Fire Cistern & Industrial Silo Spray Foam Insulation Cost in Ontario (2026 Contractor Guide)

Read Article
Fire Coatings
Fire Retardant Paint for Spray Foam Insulation in Canada: Why Only Certified 18-Mil DC315 Passes Building Code (2026)

Fire Retardant Paint for Spray Foam Insulation in Canada: Why Only Certified 18-Mil DC315 Passes Building Code (2026)

Read Article
SERVING ALL ONTARIO:Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock•Ajax • Aurora • Barrie • Belleville • Bracebridge • Brampton • Brant • Brantford • Brock • Brockville • Burlington • Caledon • Cambridge • Chatham-Kent • Clarington • Collingwood • Cornwall • East Gwillimbury • Etobicoke • Fort Erie • Gravenhurst • Grimsby • Guelph • Halton Hills • Hamilton • Huntsville • Innisfil • Kawartha Lakes • King • Kingston • Kitchener • Lincoln • London • Markham • Milton • Mississauga • Muskoka • Newmarket • Niagara Falls • North York • Oakville • Orillia • Oshawa • Ottawa • Parry Sound • Pelham • Peterborough • Pickering • Port Colborne • Richmond Hill • Sarnia • Scarborough • Scugog • St. Catharines • St. Thomas • Stratford • Thorold • Toronto • Uxbridge • Vaughan • Wainfleet • Waterloo • Welland • West Lincoln • Whitby • Whitchurch-Stouffville • Windsor • Woodstock

About Sprayfoam Solutions Toronto Inc

6,500+ projects completed since 2008. The Greater Toronto Area's trusted spray foam insulation & fireproofing contractor for commercial builders, general contractors, and homeowners.

647-333-3626Request a Quote
50 Howden Rd, Scarborough, ON M1R 3E4
100% Canadian Owned & OperatedLicensed • Up to $10M Insured • WSIB Clearance

Our Services

  • ›Spray Foam (Residential)
  • ›Spray Foam (Commercial)
  • ›Interior Sound Dampening
  • ›Fire Coating DC315
  • ›Cementitious Fireproofing
  • ›Intumescent Coating

Expert Guides

  • What is Spray Foam Insulation?
  • How Much Does Spray Foam Cost?
  • Our Chemicals & Technical Data
  • Customer Reviews (5.0 ★)
  • View Our Projects
  • Book Free On-Site Inspection

Areas We Serve

  • •Toronto & Central GTA
  • •Mississauga & Peel
  • •Oakville & Halton
  • •Vaughan & York Region
  • •Barrie & Simcoe County
  • •Muskoka & Cottage Country
  • •Waterloo & Tri-Cities
  • •Oshawa & Durham Region
  • + View All 50+ Cities
All project estimates, pricing illustrations, R-value metrics, and building code references on this website are for general informational purposes only and do not constitute a certified estimate or binding offer to contract. Formal written contracts provided by Sprayfoam Solutions Toronto Inc. following an on-site inspection strictly supersede all online representations. Subject to our Terms of Service and Privacy Policy.
AboutView Our WorkCustomer Reviews 5.0 ★CertificationsServicesAreas We ServeBlogContact UsTerms of ServicePrivacy Policy
© 2026 Spray Foam Solutions Toronto Inc. All Rights Reserved.